Carrier 42BVC manual 42BHC Unit Corner Weights lb, 42BHC Weight

Page 12

Base unit dimensions (cont)

42BHC UNIT CORNER WEIGHTS (lb)

1

 

2

 

 

2

1

4

3

 

 

 

4

3

 

 

RIGHT HAND UNIT

 

 

 

 

LEFT HAND UNIT

 

 

 

 

 

 

 

 

 

 

 

UNIT

CONFIGURATION

RIGHT-HAND UNITS

LEFT-HAND UNITS

TOTAL

42BHC

1

2

3

4

1

2

3

4

WEIGHT

 

06

No Heat

50

55

47

51

55

50

51

47

203

With Heat

50

58

59

67

58

50

67

59

234

 

08

No Heat

51

55

47

52

55

51

52

47

205

With Heat

50

59

59

68

59

50

68

59

236

 

10

No Heat

63

71

55

63

71

63

63

55

253

With Heat

62

76

68

81

76

62

81

68

287

 

12

No Heat

64

72

56

64

72

64

64

56

256

With Heat

63

76

68

82

76

63

82

68

290

 

16

No Heat

80

87

69

76

87

80

76

69

312

With Heat

79

91

82

95

91

79

95

82

346

 

20

No Heat

90

98

74

82

98

90

82

74

344

With Heat

90

102

88

100

102

90

100

88

380

 

30

No Heat

118

127

92

100

127

118

100

92

437

With Heat

118

131

106

119

131

118

119

106

474

 

40

No Heat

155

162

114

122

162

155

122

114

553

With Heat

155

166

129

140

166

155

140

129

590

 

NOTE: Unit weights (shown in pounds) ±10%, are based on the 8-row coil and 1 Hp motor.

12

Image 12
Contents Features/Benefits Variety of coil options reduces first cost42BHC Unit 42BVC UnitTable of contents Model number nomenclature Physical dataSize Nominal Cfm Coil Rows Options and accessories Factory-installed optionsField-installed accessories 42BHC, BVC Options and AccessoriesThermostat Functions AuxBase unit dimensions 42BHC FAN Coil Base Unit no ControlsUnit 42BHC42BHC FAN Coil with Motor Control Option 42BHC FAN Coil with Electric Heat Option Dimensions Supply Duct Return Duct 42BVC FAN Coil Base Unit no Controls42BVC Fan Size42BVC FAN Coil with Motor Control Option Dimensions 42BVC FAN Coil with Electric Heat Option42BHC Unit Corner Weights lb 42BHC Weight42BVC Unit Corner Weights lb Total Weight Unit Correction Factor lbAccessory dimensions Mixing BOX42BHC,BVC Unit SizeMixing BOX Rails Valve Packages Piping Size CloseOFF Piping Connection Location Diagram Head Stub OUT Sizes Row Coil SONominal Heat Options 42BHC,BVC Coil Rows Application data Basic definitionsUnit Hand Piping Components Piping Components WAY Motorized Valve Electric Selection procedure FormulasPerformance data 42BHC,BVC Airflow Correction FactorsDirect Expansion DX Correction Factors Altitude Cooling Correction Factors42BHC, BVC Nominal Cooling Capacities 42BHC,BVC Nominal Heating Capacities42BHC,BVC 4-ROW Cooling Capacity by Gpm 42BHC,BVC 6-ROW Cooling Capacity by Gpm42BHC,BVC 8-ROW Cooling Capacity by Gpm 42BHC,BVC 4-ROW Cooling Capacity by ∆T42BHC, BVC 6-ROW Cooling Capacity by ∆T 42BHC, BVC 8-ROW Cooling Capacity by ∆TCFM Suction 42BHC,BVC Temp F Unit Horsepower Data Table Size Blower CFM 42BHC,BVCRpm Bhp Unit Horsepower Data Table 42BHC,BVC Component Static Resistance in. wg Cv Factor by Coil and Unit SizeRow FilterSound Power Data 42BHC,BVC Unit Size Nominal CFMCenter Frequency Hz 125 250 1000 2000 4000Typical wiring schematics Page Typical wiring schematics Service Switches Electrical data42BHC,BVC Electric Heater Data Availability Motor Performance Data AmpsStandard control features ControlsMotor control options Motor and electric heat control optionsGuide specifications System Fan Coil UnitCarrier Corporation Syracuse, New York 05A