Carrier 42BVC, 42BHC Piping Connection Location Diagram, Head Stub OUT Sizes Row Coil SO, Nominal

Page 17

PIPING CONNECTION LOCATION DIAGRAM*

HWR

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

HWS

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

2(51)

 

 

 

 

 

 

 

1-5/8(41)

 

 

 

 

 

 

 

 

E

F

8-5/8(219)

G

6-7/8 (175)

H

0

RH Tell-Tale

LH Tell-Tale

10-3/(264)8

 

 

CWR

CWS

Drain

0

LEGEND

CWR — Cold Water Return

CWS — Cold Water Supply

HWR — Hot Water Return

HWS — Hot Water Supply

LH — Left Hand

RH — Right Hand

SO — Stub Out

*Right-hand unit with re-heat coil shown.

Use the table on the next page to determine the location of the piping connections. For example, on a size 20 unit with 4 rows and a right hand connection, the location of the chilled water supply line is deter- mined by G (6 in.) and B (74/5 in.).

42BHC,BVC

 

 

HEAD STUB OUT SIZES (in.)

 

 

8 Row Coil SO

6 Row Coil SO

4 Row Coil SO

Heating 1 or 2 SO

UNIT SIZE

Nominal

Nominal

Nominal

Row Coil Nominal

 

 

06

 

1

0.75

0.75

0.5

08

 

1

0.75

0.75

0.5

10

 

1

0.75

0.75

0.5

12

 

1

0.75

0.75

0.5

16

 

1

1

1

0.5

20

 

1

1

1

0.5

30

 

1.5

1.5

1.5

0.5

40

 

1.5

1.5

1.5

0.5

17

Image 17
Contents Variety of coil options reduces first cost Features/Benefits42BHC Unit 42BVC UnitTable of contents Size Nominal Cfm Coil Rows Model number nomenclaturePhysical data Factory-installed options Options and accessoriesField-installed accessories 42BHC, BVC Options and AccessoriesAux Thermostat Functions42BHC FAN Coil Base Unit no Controls Base unit dimensionsUnit 42BHC42BHC FAN Coil with Motor Control Option 42BHC FAN Coil with Electric Heat Option 42BVC FAN Coil Base Unit no Controls Dimensions Supply Duct Return Duct42BVC Fan Size42BVC FAN Coil with Motor Control Option 42BVC FAN Coil with Electric Heat Option Dimensions42BHC Weight 42BHC Unit Corner Weights lbTotal Weight Unit Correction Factor lb 42BVC Unit Corner Weights lbMixing BOX Accessory dimensions42BHC,BVC Unit SizeMixing BOX Rails OFF Valve PackagesPiping Size Close Nominal Piping Connection Location DiagramHead Stub OUT Sizes Row Coil SO Heat Options 42BHC,BVC Coil Rows Unit Hand Piping Components Application dataBasic definitions Piping Components WAY Motorized Valve Electric Formulas Selection procedure42BHC,BVC Airflow Correction Factors Performance dataDirect Expansion DX Correction Factors Altitude Cooling Correction Factors42BHC,BVC Nominal Heating Capacities 42BHC, BVC Nominal Cooling Capacities42BHC,BVC 6-ROW Cooling Capacity by Gpm 42BHC,BVC 4-ROW Cooling Capacity by Gpm42BHC,BVC 4-ROW Cooling Capacity by ∆T 42BHC,BVC 8-ROW Cooling Capacity by Gpm42BHC, BVC 8-ROW Cooling Capacity by ∆T 42BHC, BVC 6-ROW Cooling Capacity by ∆TCFM Suction 42BHC,BVC Temp F Rpm Bhp Unit Horsepower Data TableSize Blower CFM 42BHC,BVC Unit Horsepower Data Table Cv Factor by Coil and Unit Size 42BHC,BVC Component Static Resistance in. wgRow Filter42BHC,BVC Unit Size Nominal CFM Sound Power DataCenter Frequency Hz 125 250 1000 2000 4000Typical wiring schematics Page Typical wiring schematics Electrical data Service Switches42BHC,BVC Electric Heater Data Availability Motor Performance Data AmpsControls Standard control featuresMotor control options Motor and electric heat control optionsSystem Fan Coil Unit Guide specificationsCarrier Corporation Syracuse, New York 05A