Carrier 42BHC manual 42BVC Unit Corner Weights lb, Total Weight Unit Correction Factor lb

Page 13

 

42BVC UNIT CORNER WEIGHTS (lb)

 

1

 

 

2

3

2

1

4

4

 

3

 

 

 

1

 

 

 

 

 

 

 

 

 

 

2

 

3

 

 

 

 

2

 

 

1

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

3

 

 

 

 

 

RIGHT HAND UNIT

 

 

 

 

 

 

 

 

LEFT HAND UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

CONFIGURATION

RIGHT-HAND UNITS

 

LEFT-HAND UNITS

 

TOTAL

 

42BVC

 

1

 

2

3

4

 

1

2

3

4

 

WEIGHT

 

 

 

 

 

 

 

06

 

No Heat

52

 

54

51

43

 

54

52

43

51

 

200

 

 

With Heat

58

 

65

61

47

 

65

58

47

61

 

231

 

 

 

 

 

 

 

 

08

 

No Heat

53

 

55

51

43

 

55

53

43

51

 

202

 

 

With Heat

58

 

66

62

47

 

66

58

47

62

 

233

 

 

 

 

 

 

 

 

10

 

No Heat

63

 

69

61

50

 

69

63

50

31

 

243

 

 

With Heat

69

 

81

72

54

 

81

69

54

72

 

277

 

 

 

 

 

 

 

 

12

 

No Heat

64

 

70

62

51

 

70

64

51

62

 

247

 

 

With Heat

70

 

82

73

55

 

82

70

55

73

 

281

 

 

 

 

 

 

 

 

16

 

No Heat

74

 

85

72

58

 

85

74

58

72

 

289

 

 

With Heat

80

 

98

84

61

 

98

80

61

84

 

323

 

 

 

 

 

 

 

 

20

 

No Heat

90

 

108

86

68

 

108

90

68

86

 

351

 

 

With Heat

95

 

123

99

71

 

123

95

71

99

 

387

 

 

 

 

 

 

 

 

30

 

No Heat

110

 

139

106

81

 

139

110

81

106

 

436

 

 

With Heat

115

 

155

120

83

 

155

115

83

120

 

473

 

 

 

 

 

 

 

 

40

 

No Heat

131

 

172

125

94

 

172

131

94

125

 

522

 

 

With Heat

135

 

190

140

95

 

190

135

94

140

 

559

 

 

 

 

 

 

 

 

NOTE: Unit weights (shown in pounds) ±10% are based on the 8-row coil and 1 Hp motor.

TOTAL WEIGHT UNIT CORRECTION FACTOR (lb)

Corner weights on pages 12 and 13 are for 8-row water filled coils. For a different number of rows, total unit weight can be determined by the following procedure:

Identify the number of rows and the size of the unit.

Determine the total weight of the unit from the Corner Weight tables.

From the table below, identify the correction factor (for size of unit and number of rows) and subtract this from the total weight.

UNITS

4 ROWS

5 ROWS

6 ROWS

7 ROWS

42BHC,BVC

 

Correction Factors (lb)

 

06

21

16

11

5

08

21

16

11

5

10

28

21

14

7

12

28

21

14

7

16

39

29

20

10

20

46

35

23

12

30

74

55

37

18

40

98

74

49

25

13

Image 13
Contents Variety of coil options reduces first cost Features/Benefits42BHC Unit 42BVC UnitTable of contents Physical data Model number nomenclatureSize Nominal Cfm Coil Rows Factory-installed options Options and accessoriesField-installed accessories 42BHC, BVC Options and AccessoriesAux Thermostat Functions42BHC FAN Coil Base Unit no Controls Base unit dimensionsUnit 42BHC42BHC FAN Coil with Motor Control Option 42BHC FAN Coil with Electric Heat Option 42BVC FAN Coil Base Unit no Controls Dimensions Supply Duct Return Duct42BVC Fan Size42BVC FAN Coil with Motor Control Option 42BVC FAN Coil with Electric Heat Option Dimensions42BHC Weight 42BHC Unit Corner Weights lbTotal Weight Unit Correction Factor lb 42BVC Unit Corner Weights lbMixing BOX Accessory dimensions42BHC,BVC Unit SizeMixing BOX Rails Piping Size Close Valve PackagesOFF Head Stub OUT Sizes Row Coil SO Piping Connection Location DiagramNominal Heat Options 42BHC,BVC Coil Rows Basic definitions Application dataUnit Hand Piping Components Piping Components WAY Motorized Valve Electric Formulas Selection procedure42BHC,BVC Airflow Correction Factors Performance dataDirect Expansion DX Correction Factors Altitude Cooling Correction Factors42BHC,BVC Nominal Heating Capacities 42BHC, BVC Nominal Cooling Capacities42BHC,BVC 6-ROW Cooling Capacity by Gpm 42BHC,BVC 4-ROW Cooling Capacity by Gpm42BHC,BVC 4-ROW Cooling Capacity by ∆T 42BHC,BVC 8-ROW Cooling Capacity by Gpm42BHC, BVC 8-ROW Cooling Capacity by ∆T 42BHC, BVC 6-ROW Cooling Capacity by ∆TCFM Suction 42BHC,BVC Temp F Size Blower CFM 42BHC,BVC Unit Horsepower Data TableRpm Bhp Unit Horsepower Data Table Cv Factor by Coil and Unit Size 42BHC,BVC Component Static Resistance in. wgRow Filter42BHC,BVC Unit Size Nominal CFM Sound Power DataCenter Frequency Hz 125 250 1000 2000 4000Typical wiring schematics Page Typical wiring schematics Electrical data Service Switches42BHC,BVC Electric Heater Data Availability Motor Performance Data AmpsControls Standard control featuresMotor control options Motor and electric heat control optionsSystem Fan Coil Unit Guide specificationsCarrier Corporation Syracuse, New York 05A