CAUTION - NOTICE TO RIGGERS:

ALL PANELS MUST BE IN PLACE WHEN RIGGING. DO NOT ATTEMPT TO FORK THESE UNITS IF NO SKID IS SUPPLIED.

NOTES:

1.1.50 dia. (38.1mm) lifting holes provided for field supplied clevis.

2.Rig with a minimum of 25 ft (7620mm) length chains or cables.

3. If central lifting point is used, it must be a minimum of 13 ft. (3962mm) above the top of the unit.

4.Spreader bars made from steel or double nailed, and notched 2x6's approximately 8 ft. (2438mm) long, must be placed just above the top of the unit (and stacks) to reduce the risk of damage to the top of the unit and coils.

5.If overhead rigging is not available, the unit can be moved on rollers or dragged. When unit is moved on rollers, the unit skid, if equipped, must be removed. To lift the unit, use jacks at the rigging points. Use a minimum of one roller every 6 ft. (1829mm) to distribute the load. If the unit is to be dragged, lift the unit as described above, and place unit on a pad. Apply moving force to the pad, not the unit. When in its final location, raise the unit and remove the pad.

6.Check bill of lading for shipping weight of unit.

a30-4428

Fig. 18 — Unit Rigging Label Detail 30XA400-500

Minimum Loop Volume — The preferred minimum loop vol- ume is dependent on the type of application. In order to obtain leaving water temperature stability for comfort cooling appli- cations, a minimum of 3 gallons per ton (3.25 liters per kW) is required on all unit sizes. For process cooling applications, ap- plications where high stability is critical, or operation at ambient temperatures below 32 F (0° C) is expected, the loop volume should be increased to 6 to 10 gallons per ton (6.46 to

10.76liters per kW) of cooling. In order to achieve this volume, it may be necessary to add a water storage tank to the water loop. If a storage tank is added to the system, it should be properly vented so that the tank can be completely filled and all air eliminated. Failure to do so could cause lack of pump stabil- ity and poor system operation. Any storage tank that is placed in the water loop should have internal baffles to allow thorough mixing of the fluid. See Fig. 24.

System Piping — Proper system design and installation proce- dures should be followed closely. The system must be constructed with pressure tight components and thoroughly tested for installation leaks. Factory-supplied hydronic systems are available with single or dual (for back-up) pumps. The factory-installed system includes all of the components above the line in Fig. 25 and 26.

Installation of water systems should follow sound engineer- ing practice as well as applicable local and industry standards. Improperly designed or installed systems may cause unsatis- factory operation and/or system failure. Consult a water treatment specialist or appropriate literature for information regarding filtration, water treatment, and control devices. Fig- ures 25 and 26 show a typical installation with components that might be installed with the hydronic package of the 30XA unit.

46

Image 46
Contents Installation Instructions Place, Mount, and Rig the Unit AquaForce Chiller Model Number Designation A30-440130XA080 Air-Cooled Liquid Chiller Dimensions Right END View A30-4403100 4404090 110A30-4405 30XA090-120 Air-Cooled Liquid Chiller with Pump Dimensions Front View 160 140115.88 115.64Back View A30-440730XA140,160 Air-Cooled Liquid Chiller with Pump Dimensions 2300 30XA180,200 Air-Cooled Liquid Chiller Dimensions A30-4174 220 46.17 171.42 240 46.23 170.83 A30-4409614 532 208 132 1500 4260 4798 4799 5221 8363 300 260280 A30-4177614 532 208 132 1900 5011 5747 5760 6184 9555 A30-4178325 350614 532 208 132 1900 6205 6941 6954 7378 10750 A30-4181 4182 A30Left END View Front View A30 500 450A30-4183 A30-418 A30-41 Back View Unit Mounting Weights Units with Mchx Condenser Coils 30XA140,160 30XA080 30XA220-30030XA090-120 30XA325-350 30XA400-50030XA090-120 30XA140,160 A30-4421Dual Pump Units English Unit Mounting Weights Units with Al/Cu Condenser Coils Cooler Side ED CBA K L M N O P Compressor Side FG HIJ 1273 2898 1160 972 2089 1271 662 1273 3106 1248 972 2089 1271 959 Unit Mounting Weights Units with Cu/CU Condenser Coils 30XA080 30XA090-1201394 3139 1280 1093 2330 1392 10,627 Do not use a forklift truck to move the units A30-4420 A30-4421Physical Data, 30XA080-500 English Unit 30XAPhysical Data, 30XA080-500 SI Refrigerant Charge kg Ckt A/Ckt B/Ckt C MchxUnit Rigging Label Detail 30XA080-200 A30-4427A30-4428 Unit Rigging Label Detail 30XA400-500 30XA Typical Piping and Wiring Units with Hydronic Package Cooler Option Dimensions A30-4413A30-4417 A30-4418A30-4138 A30-4414A30-4415 PT Hydronic Pump PackageA30-4002 Thermal Flow Sensor A30-343230XA Minimum and Maximum Cooler Flow Rates Minimum Maximum NominalDetail a 30XA080-12030XA140-500 A30-3997A30-4411 A30-441230XA Pump Impeller Sizes090-160 FTV-5 Rpm Impeller Dia30XA120 30XA090,10030XA110 30XA140A30-4439 A30-4436A30-4437 A30-44403450 RPM Page Make Electrical Connections NON-FUSED Disconnect Unit Voltage Number No Hydronic Package Unit Voltage Number Unit Voltage Number No Hydronic Package 460-60 414 506 10/6 115 575-60 518 633 380-60 342 418 Unit Voltage Number Unit Voltage Number No Hydronic Package 230-60 207 253 592.4 800 869.3 700 607.0 883.9 115 30XA140-500 Electrical Data, Dual Point High Ambient Option 460-60 414 506 10/6 115 575-60 518 633 380-60 342 418 230-60 207 253 383.8/256.9 600/350 660.8/436.2 450/300 115 Power and Control Connections Compressor and Fan Electrical Data Unit Cond Size FansPump Electrical Data CCN Communication Bus WiringA30-4001 A30-3999 A30-4000Refrigerant Charge Page Copyright 2009 Carrier Corporation
Related manuals
Manual 8 pages 25.4 Kb

30XA080-500 specifications

The Carrier 30XA080-500 is a sophisticated air-cooled chiller designed for large commercial and industrial applications, renowned for its energy efficiency and reliability. This model is part of Carrier's extensive range of chillers, providing an optimal solution for space cooling needs while supporting sustainability goals.

One of the main features of the 30XA080-500 is its advanced scroll compressor technology. This design not only enhances the chiller's efficiency but also ensures quieter operation. The compressors operate with a high efficiency at partial loads, making the 30XA080-500 ideal for buildings with varying cooling demands. The unit also incorporates multiple compressors, allowing for enhanced reliability through redundancy; if one compressor fails, others can maintain performance.

The 30XA080-500 is equipped with high-performance evaporators and condensers which facilitate superior heat exchange. The unit features a fin-and-tube heat exchanger design, optimized for maximum surface area and minimal air resistance, thus enhancing overall performance. Moreover, the chiller is built with microchannel technology, which significantly reduces the refrigerant charge while improving efficiency through better heat transfer.

In terms of controls, the Carrier 30XA080-500 utilizes advanced VFD (Variable Frequency Drive) technology. This allows the system to adjust motor speed to match building loads, further increasing efficiency and reducing energy consumption. The intuitive control options enable users to monitor performance and make adjustments easily, helping optimize system operations in real time.

Another highlight of the 30XA080-500 is its environmentally conscious refrigerant, R-410A, which is known for its low Global Warming Potential (GWP). This makes the unit compliant with current and future environmental regulations, ensuring that users can operate within legal limits while reducing their carbon footprint.

The durability of the 30XA080-500 is enhanced by a rugged construction designed to withstand various weather conditions, making it suitable for outdoor installation. Insulated panels and protective coatings guard against corrosion, extending the lifespan of components and reducing maintenance costs.

In conclusion, the Carrier 30XA080-500 is a high-efficiency chiller that offers advanced technology, reliable performance, and environmental consciousness, making it an excellent choice for modern commercial buildings seeking to balance cooling needs with sustainability and energy savings. Its combination of innovative features positions it as a leader in the chiller market.