Carrier 30XA080-500 specifications 230-60 207 253 592.4 800 869.3 700 607.0 883.9 115

Page 70

Table 7 — 30XA140-500 Electrical Data, Single Point (High Ambient Option) (cont)

 

UNIT VOLTAGE

NUMBER

 

10 HP PUMP, 3450 RPM

 

 

15 HP PUMP, 3450 RPM

 

CONTROL CIRCUIT

UNIT

V-Hz

Supplied

OF

 

 

 

ICF

Rec

 

 

 

ICF

Rec

Voltage

MCA

30XA

 

 

COND

MCA

MOCP

 

 

 

Fuse

MCA

MOCP

 

 

 

Fuse

1 PH,

and

 

 

 

 

 

 

 

 

 

(3 Ph)

Min

Max

FANS

 

 

WD

 

XL

Size

 

 

WD

 

XL

Size

60 Hz

MOCP

 

230-60

207

253

10

592.4

800

869.3

 

700

607.0

800

883.9

 

700

115

40

140

200-60

187

220

10

652.4

800

986.5

 

800

668.6

800

1002.6

 

800

115

40

460-60

414

506

10

296.2

400

434.7

 

1066.7

350

303.5

400

442.0

 

1074.0

350

115

40

 

575-60

518

633

10

228.4

300

344.6

 

850.6

300

234.3

300

350.5

 

856.5

300

115

40

 

380-60

342

418

10

346.7

450

523.0

 

1288.0

400

355.5

500

531.9

 

1296.9

400

115

40

 

230-60

207

253

10

673.1

800

1067.1

 

800

687.7

800

1081.7

 

800

115

40

160

200-60

187

220

10

740.5

1000

1213.0

 

1000

756.6

1000

1229.1

 

1000

115

40

460-60

414

506

10

335.7

450

533.2

 

1341.2

400

343.0

450

540.5

 

1348.5

400

115

40

 

575-60

518

633

10

259.4

350

424.3

 

1070.3

300

265.2

350

430.1

 

1076.1

300

115

40

 

380-60

342

418

10

393.3

500

641.2

 

1620.2

450

402.1

500

650.0

 

1629.0

450

115

40

 

230-60

207

253

12

 

 

115

40

180

200-60

187

220

12

 

 

115

40

460-60

414

506

12

 

 

115

40

 

575-60

518

633

12

 

 

115

40

 

380-60

342

418

12

 

 

115

40

 

230-60

207

253

12

 

 

115

40

200

200-60

187

220

12

 

 

115

40

460-60

414

506

12

 

 

115

40

 

575-60

518

633

12

 

 

115

40

 

380-60

342

418

12

 

 

115

40

 

230-60

207

253

13

 

 

115

40

220

200-60

187

220

13

 

 

115

40

460-60

414

506

13

 

 

115

40

 

575-60

518

633

13

 

 

115

40

 

380-60

342

418

13

 

 

115

40

 

230-60

207

253

13

 

 

115

40

240

200-60

187

220

13

 

 

115

40

460-60

414

506

13

 

 

115

40

 

575-60

518

633

13

 

 

115

40

 

380-60

342

418

13

 

 

115

40

260

460-60

414

506

15

 

 

115

40

575-60

518

633

15

 

 

115

40

 

380-60

342

418

15

 

 

115

40

280

460-60

414

506

16

 

 

115

40

575-60

518

633

16

 

 

115

40

 

380-60

342

418

16

 

 

115

40

300

460-60

414

506

16

 

 

115

40

575-60

518

633

16

 

 

115

40

 

380-60

342

418

16

 

 

115

40

325

460-60

414

506

18

 

 

115

40

575-60

518

633

18

 

 

115

40

 

380-60

342

418

18

 

 

115

40

350

460-60

414

506

18

 

 

115

40

575-60

518

633

18

 

 

115

40

 

380-60

342

418

18

 

 

115

40

400

460-60

414

506

20

 

 

115

50

575-60

518

633

20

 

 

115

50

 

380-60

342

418

20

 

 

115

50

450

460-60

414

506

22

 

 

115

50

575-60

518

633

22

 

 

115

50

 

380-60

342

418

22

 

 

115

50

500

460-60

414

506

22

 

 

115

50

575-60

518

633

22

 

 

115

50

 

380-60

342

418

22

 

 

115

50

 

 

LEGEND

ICF

Instantaneous Current Flow

MCA

Minimum Circuit Amps

MOCP —

Maximum Overcurrent Protection

WD

Wye-Delta

XL

Across-the-Line

NOTES:

1.Units are suitable for use on electrical systems where voltage supplied to the unit ter- minals is not below or above the listed minimum and maximum limits. Maximum allow- able phase imbalance is: voltage, 2%; amps 10%.

2.Cooler heater is wired into the control circuit so it is always operable as long as the control power supply disconnect is on, even if any safety device is open.

3.For MCA that is less than or equal to 380 amps, 3 conductors are required.

For MCA between 381-760 amps, 6 conductors are required.

For MCA between 761-1140 amps, 9 conductors are required.

For MCA between 1141-1520 amps, 12 conductors are required.

Calculation of conductors required is based on 75 C copper wire.

4.Wiring for main field supply must be rated 75 C minimum. Use copper for all units.

a.Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to 500 kcmil.

b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to 500 kcmil.

c.Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is 1/0 to 500 kcmil.

d.Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is 250 kcmil to 500 kcmil.

5.Data provided circuit 1/circuit 2 where there are two circuits.

70

Image 70
Contents Installation Instructions Place, Mount, and Rig the Unit AquaForce Chiller Model Number Designation A30-440130XA080 Air-Cooled Liquid Chiller Dimensions Right END View A30-4403100 4404090 110A30-4405 30XA090-120 Air-Cooled Liquid Chiller with Pump Dimensions Front View 160 140115.88 115.64Back View A30-440730XA140,160 Air-Cooled Liquid Chiller with Pump Dimensions 2300 30XA180,200 Air-Cooled Liquid Chiller Dimensions A30-4174 220 46.17 171.42 240 46.23 170.83 A30-4409614 532 208 132 1500 4260 4798 4799 5221 8363 300 260280 A30-4177614 532 208 132 1900 5011 5747 5760 6184 9555 A30-4178325 350614 532 208 132 1900 6205 6941 6954 7378 10750 A30-4181 4182 A30Left END View Front View A30 500 450A30-4183 A30-418 A30-41 Back View Unit Mounting Weights Units with Mchx Condenser Coils 30XA140,160 30XA080 30XA220-30030XA090-120 30XA325-350 30XA400-50030XA090-120 30XA140,160 A30-4421Dual Pump Units English Unit Mounting Weights Units with Al/Cu Condenser Coils Cooler Side ED CBA K L M N O P Compressor Side FG HIJ 1273 2898 1160 972 2089 1271 662 1273 3106 1248 972 2089 1271 959 Unit Mounting Weights Units with Cu/CU Condenser Coils 30XA080 30XA090-1201394 3139 1280 1093 2330 1392 10,627 Do not use a forklift truck to move the units A30-4420 A30-4421Physical Data, 30XA080-500 English Unit 30XAPhysical Data, 30XA080-500 SI Refrigerant Charge kg Ckt A/Ckt B/Ckt C MchxUnit Rigging Label Detail 30XA080-200 A30-4427A30-4428 Unit Rigging Label Detail 30XA400-500 30XA Typical Piping and Wiring Units with Hydronic Package Cooler Option Dimensions A30-4413A30-4417 A30-4418A30-4138 A30-4414A30-4415 PT Hydronic Pump PackageA30-4002 Thermal Flow Sensor A30-343230XA Minimum and Maximum Cooler Flow Rates Minimum Maximum NominalDetail a 30XA080-12030XA140-500 A30-3997A30-4411 A30-441230XA Pump Impeller Sizes090-160 FTV-5 Rpm Impeller Dia30XA120 30XA090,10030XA110 30XA140A30-4439 A30-4436A30-4437 A30-44403450 RPM Page Make Electrical Connections NON-FUSED Disconnect Unit Voltage Number No Hydronic Package Unit Voltage Number Unit Voltage Number No Hydronic Package 460-60 414 506 10/6 115 575-60 518 633 380-60 342 418 Unit Voltage Number Unit Voltage Number No Hydronic Package 230-60 207 253 592.4 800 869.3 700 607.0 883.9 115 30XA140-500 Electrical Data, Dual Point High Ambient Option 460-60 414 506 10/6 115 575-60 518 633 380-60 342 418 230-60 207 253 383.8/256.9 600/350 660.8/436.2 450/300 115 Power and Control Connections Compressor and Fan Electrical Data Unit Cond Size FansPump Electrical Data CCN Communication Bus WiringA30-4001 A30-3999 A30-4000Refrigerant Charge Page Copyright 2009 Carrier Corporation
Related manuals
Manual 8 pages 25.4 Kb

30XA080-500 specifications

The Carrier 30XA080-500 is a sophisticated air-cooled chiller designed for large commercial and industrial applications, renowned for its energy efficiency and reliability. This model is part of Carrier's extensive range of chillers, providing an optimal solution for space cooling needs while supporting sustainability goals.

One of the main features of the 30XA080-500 is its advanced scroll compressor technology. This design not only enhances the chiller's efficiency but also ensures quieter operation. The compressors operate with a high efficiency at partial loads, making the 30XA080-500 ideal for buildings with varying cooling demands. The unit also incorporates multiple compressors, allowing for enhanced reliability through redundancy; if one compressor fails, others can maintain performance.

The 30XA080-500 is equipped with high-performance evaporators and condensers which facilitate superior heat exchange. The unit features a fin-and-tube heat exchanger design, optimized for maximum surface area and minimal air resistance, thus enhancing overall performance. Moreover, the chiller is built with microchannel technology, which significantly reduces the refrigerant charge while improving efficiency through better heat transfer.

In terms of controls, the Carrier 30XA080-500 utilizes advanced VFD (Variable Frequency Drive) technology. This allows the system to adjust motor speed to match building loads, further increasing efficiency and reducing energy consumption. The intuitive control options enable users to monitor performance and make adjustments easily, helping optimize system operations in real time.

Another highlight of the 30XA080-500 is its environmentally conscious refrigerant, R-410A, which is known for its low Global Warming Potential (GWP). This makes the unit compliant with current and future environmental regulations, ensuring that users can operate within legal limits while reducing their carbon footprint.

The durability of the 30XA080-500 is enhanced by a rugged construction designed to withstand various weather conditions, making it suitable for outdoor installation. Insulated panels and protective coatings guard against corrosion, extending the lifespan of components and reducing maintenance costs.

In conclusion, the Carrier 30XA080-500 is a high-efficiency chiller that offers advanced technology, reliable performance, and environmental consciousness, making it an excellent choice for modern commercial buildings seeking to balance cooling needs with sustainability and energy savings. Its combination of innovative features positions it as a leader in the chiller market.