Carrier 30XA080-500 specifications 30XA Typical Piping and Wiring Units with Hydronic Package

Page 47

FD

CONTROL

BALANCING VALVE/

SHUT OFF*

VIBRATION

ELIMINATORS*

PUMP

POWER

FD

STRAINER*

GATE VALVE*

DRAIN

PRESSURE/

a30-4114

SHUTOFF

TEMPERATURE TAPS*

VALVE

 

 

LEGEND

FD — Fused Disconnect

Airflow Through Condenser

Chilled Water Piping

Power Wiring

*Field-installed.

NOTES:

1.Chiller must be installed level to maintain proper compressor oil return.

2.Piping shown are general points-of-connection guides only and are not intended for a specific installation. Wiring and piping shown are for a quick overview of system and are not in accordance with recognized standards.

3.All wiring must comply with applicable local and national codes.

4.All piping must follow standard piping techniques. Refer to Carrier System Design Manual or appropriate ASHRAE (American Society of Heating, Refrigeration, and Air Conditioning Engineers) handbook for details.

5.A 20 mesh strainer is required withinh 10 ft (3 m) of the cooler.

Fig. 19A — 30XA Typical Piping and Wiring (Units without Hydronic Package)

 

AIRFLOW

 

FIELD-SUPPLIED

FIELD-SUPPLIED

FUSED DISCONNECT

UNIT POWER

FUSED DISCONNECT

 

CONTROL POWER

 

NOTES:

1.

Chiller must be installed level to maintain proper

 

compressor oil return and hydraulics.

2.

Wiring and piping shown are general points-of-

 

connection guides only and are not intended for a

 

specific installation. Wiring and piping shown are

 

for a quick overview of system and are not in

 

accordance with recognized standards.

BALANCING VALVE/

PRESSURE/

 

SHUTOFF*

 

TEMPERATURE

 

 

 

 

TAPS*

 

 

VIBRATION

DRAIN SHUTOFF VALVE

 

 

 

ELIMINATORS*

 

3.

All wiring must comply with applicable local and

 

national codes.

4.

All piping must follow standard piping techniques.

 

Refer to Carrier System Design Manual or appro-

 

priate ASHRAE (American Society of Heating,

 

Refrigeration, and Air Conditioning Engineers)

 

handbook for details.

STRAINER*

GATE VALVE*

LEGEND

Airflow Through Condenser

Power Wiring

Chilled Water Piping

5.

Air separator required as close to chiller as possi-

 

ble (except primary/secondary systems).

6.

20 mesh strainer required for open loop systems.

PUMP*Field-installed.

Fig. 19B — 30XA Typical Piping and Wiring (Units with Hydronic Package)

47

Image 47
Contents Installation Instructions Place, Mount, and Rig the Unit A30-4401 AquaForce Chiller Model Number Designation30XA080 Air-Cooled Liquid Chiller Dimensions A30-4403 Right END View110 4404090 100A30-4405 30XA090-120 Air-Cooled Liquid Chiller with Pump Dimensions Front View 115.64 140115.88 160A30-4407 Back View30XA140,160 Air-Cooled Liquid Chiller with Pump Dimensions 2300 30XA180,200 Air-Cooled Liquid Chiller Dimensions A30-4174 A30-4409 220 46.17 171.42 240 46.23 170.83614 532 208 132 1500 4260 4798 4799 5221 8363 A30-4177 260280 300A30-4178 614 532 208 132 1900 5011 5747 5760 6184 9555350 325614 532 208 132 1900 6205 6941 6954 7378 10750 A30-4181 A30 4182Left END View Front View A30 A30-4183 450500 A30-418 A30-41 Back View Unit Mounting Weights Units with Mchx Condenser Coils 30XA400-500 30XA080 30XA220-30030XA090-120 30XA325-350 30XA140,160A30-4421 30XA090-120 30XA140,160Dual Pump Units English Unit Mounting Weights Units with Al/Cu Condenser Coils Cooler Side ED CBA K L M N O P Compressor Side FG HIJ 1273 2898 1160 972 2089 1271 662 1273 3106 1248 972 2089 1271 959 Unit Mounting Weights Units with Cu/CU Condenser Coils 30XA090-120 30XA0801394 3139 1280 1093 2330 1392 10,627 A30-4420 A30-4421 Do not use a forklift truck to move the unitsUnit 30XA Physical Data, 30XA080-500 EnglishRefrigerant Charge kg Ckt A/Ckt B/Ckt C Mchx Physical Data, 30XA080-500 SIA30-4427 Unit Rigging Label Detail 30XA080-200A30-4428 Unit Rigging Label Detail 30XA400-500 30XA Typical Piping and Wiring Units with Hydronic Package A30-4413 Cooler Option DimensionsA30-4418 A30-4417A30-4414 A30-4138PT Hydronic Pump Package A30-4415A30-4002 A30-3432 Thermal Flow SensorMinimum Maximum Nominal 30XA Minimum and Maximum Cooler Flow RatesA30-3997 30XA080-12030XA140-500 Detail aA30-4412 A30-4411Rpm Impeller Dia Pump Impeller Sizes090-160 FTV-5 30XA30XA140 30XA090,10030XA110 30XA120A30-4440 A30-4436A30-4437 A30-44393450 RPM Page Make Electrical Connections NON-FUSED Disconnect Unit Voltage Number No Hydronic Package Unit Voltage Number Unit Voltage Number No Hydronic Package 460-60 414 506 10/6 115 575-60 518 633 380-60 342 418 Unit Voltage Number Unit Voltage Number No Hydronic Package 230-60 207 253 592.4 800 869.3 700 607.0 883.9 115 30XA140-500 Electrical Data, Dual Point High Ambient Option 460-60 414 506 10/6 115 575-60 518 633 380-60 342 418 230-60 207 253 383.8/256.9 600/350 660.8/436.2 450/300 115 Power and Control Connections Unit Cond Size Fans Compressor and Fan Electrical DataA30-4001 CCN Communication Bus WiringPump Electrical Data A30-4000 A30-3999Refrigerant Charge Page Copyright 2009 Carrier Corporation
Related manuals
Manual 8 pages 25.4 Kb

30XA080-500 specifications

The Carrier 30XA080-500 is a sophisticated air-cooled chiller designed for large commercial and industrial applications, renowned for its energy efficiency and reliability. This model is part of Carrier's extensive range of chillers, providing an optimal solution for space cooling needs while supporting sustainability goals.

One of the main features of the 30XA080-500 is its advanced scroll compressor technology. This design not only enhances the chiller's efficiency but also ensures quieter operation. The compressors operate with a high efficiency at partial loads, making the 30XA080-500 ideal for buildings with varying cooling demands. The unit also incorporates multiple compressors, allowing for enhanced reliability through redundancy; if one compressor fails, others can maintain performance.

The 30XA080-500 is equipped with high-performance evaporators and condensers which facilitate superior heat exchange. The unit features a fin-and-tube heat exchanger design, optimized for maximum surface area and minimal air resistance, thus enhancing overall performance. Moreover, the chiller is built with microchannel technology, which significantly reduces the refrigerant charge while improving efficiency through better heat transfer.

In terms of controls, the Carrier 30XA080-500 utilizes advanced VFD (Variable Frequency Drive) technology. This allows the system to adjust motor speed to match building loads, further increasing efficiency and reducing energy consumption. The intuitive control options enable users to monitor performance and make adjustments easily, helping optimize system operations in real time.

Another highlight of the 30XA080-500 is its environmentally conscious refrigerant, R-410A, which is known for its low Global Warming Potential (GWP). This makes the unit compliant with current and future environmental regulations, ensuring that users can operate within legal limits while reducing their carbon footprint.

The durability of the 30XA080-500 is enhanced by a rugged construction designed to withstand various weather conditions, making it suitable for outdoor installation. Insulated panels and protective coatings guard against corrosion, extending the lifespan of components and reducing maintenance costs.

In conclusion, the Carrier 30XA080-500 is a high-efficiency chiller that offers advanced technology, reliable performance, and environmental consciousness, making it an excellent choice for modern commercial buildings seeking to balance cooling needs with sustainability and energy savings. Its combination of innovative features positions it as a leader in the chiller market.