warning

Generator produces hazardous voltage.

Failure to properly ground generator can result in electrocution.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company.

DO NOT touch bare wires or receptacles.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

If you must work around a unit while it is operating, stand on an insulated dry surface to reduce shock hazard.

DO NOT allow unqualified persons or children to operate or service generator.

In case of an accident caused by electrical shock, immediately shut down the source of electrical power and contact the local authorities. Avoid direct contact with the victim.

Despite the safe design of the home generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death.

Remain alert at all times while working on this equipment. Never work on the equipment when you are physically or mentally fatigued.

Before performing any maintenance on the generator, disconnect the battery cable indicated by a NEGATIVE, NEG or (-)first. When finished, reconnect that cable last.

After your home generator is installed, the generator may crank and start without warning any time there is a power failure. To prevent possible injury, always set the generator’s system switch to OFF AND remove the 15 Amp fuse BEFORE working on the equipment.

warning

Propane and Natural Gas are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

Install the fuel supply system according to applicable fuel-gas codes.

Before placing the home generator into service, the fuel system lines must be properly purged and leak tested.

After the generator is installed, you should inspect the fuel system periodically.

NO leakage is permitted.

DO NOT operate engine if smell of fuel is present or other explosive conditions exist.

DO NOT smoke around the generator. Wipe up any oil spills immediately. Ensure that no combustible materials are left in the generator compartment. Keep the area near the generator clean and free of debris.

warning

Hazardous Voltage

Contact with power lines can cause electric shock or burn.

Lifting Hazard / Heavy Object

Can cause muscle strain or back injury.

DO NOT contact any power lines when using required lifting/hoisting equipment.

DO NOT lift or move generator without assistance.

Use lifting pipes or straps as described in Lifting the Generator. The unit may shift during movement, which can cause injury.

DO NOT lift unit by roof as damage to generator will occur.

Image 5
Contents Series Liquid-Cooled Home Generator System Date of Purchase Generator Where to Find UsEngine Model Number Model Revision Serial NumberTable of Contents BRIGGSandSTRATTON.COM Safety RulesHazard Symbols and Meanings Page Never operate generator without protective housing or covers Installation General Location Guidelines Home Generator LocationGenerator Location Lifting the Generator Electrical and Fuel Inlet LocationsConcrete Slab Female NPTTo Open an Access Door Access DoorsTo Close an Access Door Gaseous Fuel SystemNo leakage is permitted LP Vapor Natural Fuel ConsumptionNatural Gas LP Vapor +12 Volt DC, .5 Amp Output Internal auxiliary power supply System ConnectorsPole Connector Plug To install the remote LED indicator Fault Detection SystemGenerator AC Connection System Grounding the GeneratorSystem Control Panel Final Installation ConsiderationsFuel Supply System BatteryInitial Start-up No Load Fuel ConversionSchematic / Wiring Diagram Installation Inspection Setting Exercise TimerControls OperationManual de Instalación y Arranque Fecha de compra Generador Dónde encontrarnosMotor Número de Modelo Revisión Número de SerieMandos Utilización Instrucciones importantes de seguridad InstalaciónSímbolos de Peligro y Significados Conserve estas instruccionesAte para arriba el pelo largo y quite la joyería Tensión peligrosaNo modifique al generador en ninguna forma PrecauciónInstalación Pautas Generales para la Ubicación del Generador Ubicación del Sistema de Generador de DomésticoUbicación del Generador Elevación del Generador Solera de concretoUbicación de las entradas eléctricas y de combustible Para cerrar una puerta de acceso Puertas de AccesoPara abrir una puerta de acceso Combustible, más adelante en este manual Sistema de combustible gaseosoNo encienda un cigarrillo o fume Consumo de Combustible Dimensiones de la Cañería de CombustibleGas Natural Vapor de PL Vapor de GasCableado para toma de 10 polos Conexiones de SistemaConexión a Tierra del Generador Sistema de Conexión de c.a. del GeneradorInterconexiones del Circuito de Control Sistema de Detección de FallasConsideraciones finales para la instalación Panel de Control del SistemaArranque inicial sin carga Sistema de Suministro de CombustibleConversión de combustible BateríaMandos Configuración del temporizador de prácticaUtilización Secuencia de operación automáticaBRIGGSandSTRATTON.COM Manuel d’Installation et Démarrage Date d’achat Génératrice Où nous trouverMoteur Numéro de modèle Révision Numéro de sérieCommandes Fonctionnement Directives de sécurité importantes InstallationSécurité Symboles de Danger et MoyensDirectives de sécurité importantes Tension dangereuse Avis Description de l’équipement Responsabilités de l’InstallateurResponsabilités de l’Acheteur Précautions Lors du DéballageDirectives Générales Concernant l’Emplacement Emplacement du Génératrice d’état d’AttenteInstallez l’unité à l’extérieur Seulement Dégagement Autour de la GénératriceSoulèvement de la Génératrice Dalle de bétonPortes d’Accès Instalación CommandesPour ouvrir une porte d’accès Pour fermer une porte d’accèsAucune fuite ne peut être tolérée Le système de combustible gazeuxGas Naturel Vapeur PL Consommation de CombustiblePropane Gaz Grosseur du Tuyau de CombustibleEntretien Dépannage Garantie Connexions de systèmeMise à la Masse de la Génératrice Interconnexions du Circuit de CommandeSystème de Détection des Pannes Important Le voyant DEL est sensible à la polaritéConsidérations pour l’installation finale Huile à Moteur Tableau de Commande du SystèmeInterrupteur de système Fusible de 15 AmpèresBatterie Système de refroidissementSystème d’Alimentation en Combustible Démarrage initial sans chargeCapteur de Prise en Charge de la Tension de Service CommandesFonctionnement Séquence de fonctionnement automatiqueRéglage de la minuterie de cycle d’exercice Vérification installationPage BRIGGSandSTRATTON.COM

45000 specifications

The Briggs & Stratton 45000 is a powerful generator that stands out in the realm of portable power solutions. Designed for a variety of applications, it is an ideal choice for homeowners, outdoor enthusiasts, and professionals alike. With a robust engine and advanced features, it ensures a reliable source of electricity when you need it most.

One of the key features of the Briggs & Stratton 45000 is its impressive power output. It provides starting watts of 4,500 and running watts of 3,600, making it suitable for powering essential appliances during outages or for running tools on job sites. This generator is equipped with a durable 306cc engine that utilizes a reliable overhead valve (OHV) design for enhanced performance and efficiency. This engine type ensures lower oil consumption, reduced emissions, and quieter operation compared to traditional engines.

The generator's lightweight design and integrated handle make it highly portable. Weighing approximately 107 pounds, it is easy to transport, allowing for seamless movement from one location to another. The rugged wheels provide excellent maneuverability over uneven terrain, making it a perfect companion for camping trips, tailgating events, and outdoor projects.

Another notable feature of the Briggs & Stratton 45000 is its user-friendly control panel. Equipped with multiple 120V AC outlets, it allows users to connect various devices and appliances simultaneously. The addition of a USB port facilitates charging smartphones and tablets, catering to the modern user’s needs. The generator also includes a built-in circuit breaker to protect against overloads, ensuring the safety of connected devices.

Advanced technologies further enhance the performance and usability of the Briggs & Stratton 45000. For instance, it features a digital display that keeps users informed about the voltage output and running hours. An automatic shutoff function prevents engine damage by alerting users when oil levels are low. Additionally, the generator incorporates a pressurized lubrication system that enhances longevity and minimizes wear and tear.

To top it off, the Briggs & Stratton 45000 meets various safety standards, providing peace of mind for everyone using it. With all these features combined, the Briggs & Stratton 45000 stands as a reliable and efficient portable generator that meets the diverse power needs of users across various settings. Whether at home, on the job, or enjoying the great outdoors, this generator can be counted on to deliver dependable performance.