In both these cases, the 90 degree angle for fixing the pipes’ connection to the wall plate should be shortened so that it doesn’t protrude through the rubber sleeve.
Mounting the central unit
Push in the unit so that the inlet and outlet pipes face up to each other, and the mounting brackets rest against the rubber grom- mets. Rest the left mounting of the central unit on it’s seating and then push the right end into its place. Use your hand to support the central unit and push it’s connections into the sealing grom- mets of the plate Picture 4.
Install the left locking bracket first, and then the right one. Attach the
Your unit is now ready to be used. Picture 6.
Oxy3etage
Installing a wall plate with HEPA filter
Use the wall/filter plate as a template for drilling the holes for the 4 screws. Make sure the plate is well fixed to the wall. Use plugs or expanding fittings if needed. Picture 7.
On the upper ledge of the plate is a connector to a pipe system in case that the
Mounting the unit
Move the unit towards the fibre plate so that the inlet and outlet pipes mate up and so that the mounting brackets rest against the plastic. Let the left bracket of the central unit rest against its seat and then bring the right hand one into place. Support the central unit with your hand,
and insert the connections into the sealing of the plate. Picture 9.
Install the left locking bracket first and then the right one. Then connect the power supply cable of your unit. Picture 10.
Connecting the suction hose
Suction hoses that are available in different shapes and lengths, are connected either to the
Maintaining and changing the dust bag
Changing the dust bag
Pull out the frame for the bag from the unit and remove the dust bag. Picture 13.
Install a new dust bag. Place the collar of the dust bag in the grooves. The fittings of the frame has two positions that either fit the large synthetic bag or
to the left of it. In the case of the frame being hard to move, it is probably wrongly positioned. The lid will close easily when the frame is in its proper position. Picture 14, 15.
Coarse filter
The coarse filter serves as a protection to the vacuum cleaner engine in the case the bag for any reason should brake, and will then prevent dust from entering the engine. The filter must then be cleaned by rinsing it in running water. After cleaning, the filter must be absolutely dry before using the vacuum cleaner. Picture 15.
Changing and cleaning the HEPA 12 filter of the Oxy3etage Twist the locking bracket downwards and remove the lid. Picture 16.
If the filter is washable, take it out and rinse it. Make sure it is ab- solutely dry before reinstalling it. A washable filter can be cleaned about five times. A
When refitting the lid, make sure that both studs in the top of the lid sit correctly, before fixing the locking bracket. Picture 18.
Troubleshooting
The central unit does not start
1.Is the central unit connected to the mains?
2.Check the fuses.
3.Is the low voltage cable connected to the central unit?
4.Are you using the correct suction hose? The original hose has the correct connectors.
5.The central unit does not start with any of the suction boxes. Check that the
6.Is there a break on the low voltage cable or a fault in the circuit board of the motor? The simplest way to check this is to
The central unit does not stop
1.Check the suction boxes, so that the connectors are not
2.If the central unit still does not stop, there is probably a fault in the electronics. Pull out the plug, and contact an authorised workshop.
The vacuum cleaner does not suck, as it should
1.Check that the suction boxes that are not used, are closed, and that the lid of the bag space is firmly closed, and not causing a leak.
2.Is the bag full? Change the bag!
3.Is there a leak in the pipes? Check that this is not the case by blocking the air supply of the suction pipe with the hand. If the vacuum valve opens, then the pipes are most likely not leaking.
4.Is there a blockage in the pipes? Check first that there is no blockage in the suction pipe. Then check if there is better suc- tion in some other suction box. If this is the case, then there is most likely a blockage in the pipes leading up to the first box. If the suction is bad in the other boxes as well, then check the suction directly at the unit. Do like this; Lift the unit from the wall and feel with the hand if the suction is better at the unit. If this is the case, there is a blockage in the pipes. Knowing