Page 1

Use & Care Manual

With Installation Instructions for the Installer

Direct Vent Gas

Tankless Water Heater

Paloma

PH-25RDVS (N,P)

Rheem/ Ecosense

RTG-66DV (N,P)

ECO-180DV (N,P)

Ruud RUTG-66DV (N,P)

Richmond RMTG-66DV (N,P)

!Warning: This water heater is not suitable for use in manufactured (mobile) homes!

The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, to the owner–operator, to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual also includes a parts list.

It is very important that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you don’t understand these instructions or any terms within it, seek professional advice.

Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased. If additional information is required, refer to the section on If You Need Service.

Do not destroy this manual. Please read carefully and keep in a safe place for future reference.

!Information!

California Proposition 65 Warning: This product contains

!chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.Recognize this symbol as an indication of Important Safety

WARNING: If the information in these instructions is not followed exactly, ! a fire or explosion may result, causing property damage, personal injury or death.

!FOR YOUR SAFETY!

Do not store or use gasoline or other flammable vapors or liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Do not return to your home until authorized by the gas supplier or fire department.

Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or death. Refer to this manual. Installation and service must be performed by a qualified installer, service agency or the gas supplier.

ESIG

D

N

31-92683-000

Printed in Japan

CERTIFIED

R

C

D

 

ERTIFIE

®

AP14558 (01/08)

Image 1
Contents Tankless Water Heater For Your Records Install and properly vent the water heater…  & # 0 Natural gas and liquefied petroleum models For Installations in the State of California Location of Water Heater Installing the water heaterInspect Shipment Corrosive AtmospheresVenting Lengths VentingAppliance Vent Adapter Venting Through Closed SpacesDraining the Condensate Horizontal Vent Terminal Location Canadian Installations US InstallationsAdditional Considerations Indoor Water HeaterHorizontal Vent Installation Vertical Vent Termination Location Vertical Vent InstallationThermal Expansion Mounting the Water HeaterWater Supply Connections Cold and hot water connections Lines.Air Drain Valve Shown on Right without Tubing Relief ValvePressure Testing the Gas Supply System Leak TestingGas Supply High AltitudeRemote Control Installation Projections Electrical Connection Power CordPer Foot Downward Pitch Typical Installation of Water Heater Venting RequiredDuring Installation of this water heater… Hot and Cold Pipe Insulation InstallationInsulation Blankets Indoor Water Heater Location Installation Check ListLighting the water heater Water Temperature Setting Safety PrecautionsTime/Temperature Relationship in Scalds Water Temperature Setting… Housekeeping Routine Preventative MaintenanceBurner Inspection Venting System InspectionVacation and Extended Shut-Down Condensate Trap InspectionFreeze Protection Draining the Water HeaterBefore You Call For Service… Error Code Guide Replacement Parts 135F 57C DIP If YOU Need Service