Rheem RUTG-66DV, P), PH-25RDVS, RMTG-66DV, ECO-180DV warranty Error Code Guide

Page 32

Error Code Guide:

When an error code is displayed:

Close the hot water faucet, turn off the switch on the remote control..

Wait for about 5 minutes before turning the switch on again..

Open the hot water faucet..

If the error code remains in the display:

Close the hot water faucet and turn off the switch on the remote control..

Take the proper action shown below and attempt operation of the appliance again..

If the error code is still shown:

Turn off the hot water faucet and turn off the switch on the remote control..

Take note of the error code displayed and call the customer service assistance number in the “If You Need Service” section of the manual on the back cover..

Notice: If an error code other than those listed below is displayed, immediately turn off the hot water faucet, take note of the error code, turn off the switch on the remote control and call the customer assistance number..

Error Code

Possible Cause

What To Do

11

The Gas Shutoff Valve is not opened

Open the Gas Shutoff Valve

 

completely..

completely..

 

 

 

12

Gas Service has been interrupted..

Contact Gas Utility Company..

 

LP Gas is running low.. (LP models only)

Fill up LP Gas container or replace

 

with a new cylinder of LP Gas..

 

 

15

The hot water faucet is not opened enough..

Open the faucet more to secure

 

 

enough volume..

 

 

 

05

Air intake or vent termination may be

Remove any obstructions on the air

(Every 60 seconds you hear

blocked..

intake or vent termination..

an alarm or when the faucet is

The vent pipes on the concentric vent

Contact a dealer for service..

closed, the alarm stops..)

termination may not be connected properly..

 

 

 

 

13

If the error code is still displayed after taking

Contact a dealer for service..

 

the above steps..

 

 

 

 

1L

Water heater has build up of lime deposits..

Contact a dealer for service..

 

 

 

CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING.

CAUTION: For your safety, DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.

32

Image 32
Contents Tankless Water Heater For Your Records Install and properly vent the water heater…  & # 0 Natural gas and liquefied petroleum models For Installations in the State of California Installing the water heater Location of Water HeaterCorrosive Atmospheres Inspect ShipmentVenting Venting LengthsDraining the Condensate Venting Through Closed SpacesAppliance Vent Adapter Canadian Installations US Installations Horizontal Vent Terminal LocationIndoor Water Heater Additional ConsiderationsHorizontal Vent Installation Vertical Vent Installation Vertical Vent Termination LocationWater Supply Connections Mounting the Water HeaterThermal Expansion Cold and hot water connections Lines.Air Relief Valve Drain Valve Shown on Right without TubingLeak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeRemote Control Installation Projections Power Cord Electrical ConnectionTypical Installation of Water Heater Venting Required Per Foot Downward PitchInsulation Blankets Hot and Cold Pipe Insulation InstallationDuring Installation of this water heater… Installation Check List Indoor Water Heater LocationLighting the water heater Time/Temperature Relationship in Scalds Safety PrecautionsWater Temperature Setting Water Temperature Setting… Routine Preventative Maintenance HousekeepingVenting System Inspection Burner InspectionVacation and Extended Shut-Down Condensate Trap InspectionDraining the Water Heater Freeze ProtectionBefore You Call For Service… Error Code Guide Replacement Parts 135F 57C DIP If YOU Need Service