Rheem ECO-180DV, P), PH-25RDVS, RUTG-66DV Installation Check List, Indoor Water Heater Location

Page 24

Installing the water heater:

Installation Check List

A.Indoor Water Heater Location

Close to area of vent termination..

Indoors and protected from freezing temperatures..

Proper clearance from combustible surfaces observed..

Sufficient fresh air supply for proper operation of water heater..

Air supply free of corrosive elements and flammable vapors..

Provisions made to protect area from water damage..

Sufficient room to service heater..

Combustible materials, such as clothing, cleaning materials, rags, etc.. clear of the heater and

vent piping..

Water heater is properly attached to the wall..

B.Water Supply

Water supply has sufficient pressure..

Air purged from water heater and piping..

Water connections tight and free of leaks..

Water filter is clean and in place..

Materials used are as instructed in this manual..

Water pipes are insulated and protected from freezing..

C.Gas Supply

Gas type matches rating plate..

Gas supply pressure is sufficient for the water heater..

Gas line equipped with shut-off valve, union and sediment trap..

Approved pipe joint compound used..

Soap and water solution used to check all connections and fittings for possible gas leak..

Gas Company inspected installation (if required)..

D.Relief Valve

Pressure Relief Valve properly installed and discharge line run to open drain..

Discharge line protected from freezing..

E.Co-Axial Venting

Vent pipe material should be category III and meet UL1738 in US and ULC S636 in Canada..

Connector(s) pitched (1/4” per foot of length minimum) downward or UPWARD to termination.. If UPWARD, a condensate trap must be installed close to the heater.. See page 13 and 14..

Connector(s) securely fastened together with high temperature silicone (500°F [260°C]) and air-tight..

All co-axial vent runs are properly supported..

Vent terminal is properly installed..

Sufficient combustion air is available..

Maximum and minimum vent lengths are observed..

F.Electrical Wiring

Voltage matches rating plate..

Water heater is properly grounded..

Supply cord and/or wiring meets all local codes..

24

Image 24
Contents Tankless Water Heater For Your Records Install and properly vent the water heater…  & # 0 Natural gas and liquefied petroleum models For Installations in the State of California Installing the water heater Location of Water HeaterCorrosive Atmospheres Inspect ShipmentVenting Venting LengthsVenting Through Closed Spaces Appliance Vent AdapterDraining the Condensate Canadian Installations US Installations Horizontal Vent Terminal LocationIndoor Water Heater Additional ConsiderationsHorizontal Vent Installation Vertical Vent Installation Vertical Vent Termination LocationMounting the Water Heater Thermal ExpansionWater Supply Connections Cold and hot water connections Lines.Air Relief Valve Drain Valve Shown on Right without TubingLeak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeRemote Control Installation Projections Power Cord Electrical ConnectionTypical Installation of Water Heater Venting Required Per Foot Downward PitchHot and Cold Pipe Insulation Installation During Installation of this water heater…Insulation Blankets Installation Check List Indoor Water Heater LocationLighting the water heater Safety Precautions Water Temperature SettingTime/Temperature Relationship in Scalds Water Temperature Setting… Routine Preventative Maintenance HousekeepingVenting System Inspection Burner InspectionVacation and Extended Shut-Down Condensate Trap InspectionDraining the Water Heater Freeze ProtectionBefore You Call For Service… Error Code Guide Replacement Parts 135F 57C DIP If YOU Need Service