Rheem PH-25RDVS, P), RUTG-66DV, RMTG-66DV, ECO-180DV warranty Cold and hot water connections Lines.Air

Page 16

Installing the water heater:

Water Supply Connections, continued

CAUTION: This water heater must only be used with the following water supply system conditions:

With clean, potable water free of corrosive chemicals, sand, dirt or other contaminates.

With inlet water temperatures above 32°F (0°C), but not exceeding 120°F (49°C).

Free of lime and scale deposits.

DO NOT reverse the hot and cold water connections. The water heater will

not operate.

Water Filter

Clean the

Water Filter

Water Inlet

Check Valve

Nipple

Water

Notice: Use only teflon tape on

cold and hot water connections and

lines.Air

Relief

Valve

Hot

Water

Tap

Drain Valve

This appliance is not intended for space heating application. Do not connect this heater to waterlines previously used for space heating or non-potable water distribution. All water piping and components shall be suitable for potable water.

Notice: If the water flow resistance of a shower head is too high, the burner in the water heater will fail to ignite.. Keep the shower head clean from debris that could cause additional pressure drop..

Notice: If using mixing valves on the outlet, choose one that prevents cold water pressure from overcoming hot water line pressure..

Notice: If multiple water heaters are installed in a manifold system, the water piping must be in “Parallel”. A water pressure of 40 psi (276 kPa) is recommended for each water heater for proper operation of the water heaters.

Alternate Water Piping Arrangement with Optional Valve Kit

Valve kits may be purchased and installed as optional items.. Contact your distributor or place of purchase for details..They allow for one person full diagnostic testing and ease of flushing the system.. The kit includes two full port isolation valves, one for the cold side and one for the hot side.. Refer to page 22..

Install a shutoff valve near the inlet of the water heater for service and draining purposes..

It is not recommended to use pipes with smaller diameters than the water supply connection of the water heater..

Before connecting the water supply pipe to the water heater, open the shutoff valve and clean out sand, debris, air, caulking material, etc.. inside the pipe.. Connect to the water inlet, then check water flow.. Close the shutoff valve and clean the water filter..

Be sure to connect the water inlet and the hot water outlet as shown on the water heater.. If reversed, the water heater will not function..

Installation of unions or flexible copper connections are recommended on the HOT and COLD water lines, so that the water heater may disconnect easily for servicing, if necessary..

Install a Check Valve between the water heater and the water shutoff valve (see the top left diagram)..

The following should be addressed in regards to the HOT WATER OUTLET:

Connections between the water heater and point(s) of use should be as short and direct as possible..

Local codes shall govern the exact type of pipe material to be used for water connections..

To conserve energy and minimize heat loss, insulation of hot water piping is recommended (see Hot and Cold Pipe Insulation Installation on page 23)..

Notice: The flow rate of hot water may vary when more than two faucets (appliances, fixtures, etc..) are being used simultaneously..

Notice: The pipes MUST be completely drainable.. If the hot water faucets are located at a point higher than the water heater, place a drain valve at the lowest point (see diagram at the left)..

16

Image 16
Contents Tankless Water Heater For Your Records Install and properly vent the water heater…  & # 0 Natural gas and liquefied petroleum models For Installations in the State of California Installing the water heater Location of Water HeaterCorrosive Atmospheres Inspect ShipmentVenting Venting LengthsAppliance Vent Adapter Venting Through Closed SpacesDraining the Condensate Canadian Installations US Installations Horizontal Vent Terminal LocationIndoor Water Heater Additional ConsiderationsHorizontal Vent Installation Vertical Vent Installation Vertical Vent Termination LocationThermal Expansion Mounting the Water HeaterWater Supply Connections Cold and hot water connections Lines.Air Relief Valve Drain Valve Shown on Right without TubingLeak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeRemote Control Installation Projections Power Cord Electrical ConnectionTypical Installation of Water Heater Venting Required Per Foot Downward PitchDuring Installation of this water heater… Hot and Cold Pipe Insulation InstallationInsulation Blankets Installation Check List Indoor Water Heater LocationLighting the water heater Water Temperature Setting Safety PrecautionsTime/Temperature Relationship in Scalds Water Temperature Setting… Routine Preventative Maintenance HousekeepingVenting System Inspection Burner InspectionVacation and Extended Shut-Down Condensate Trap InspectionDraining the Water Heater Freeze ProtectionBefore You Call For Service… Error Code Guide Replacement Parts 135F 57C DIP If YOU Need Service