Rheem RUTG-66DV, P), PH-25RDVS, RMTG-66DV Relief Valve, Drain Valve Shown on Right without Tubing

Page 17

Drain Valve

shown on

right without

tubing..

Drain

Valve

Pressure

Relief

Valve

 

Union

 

 

 

Water

 

 

 

Shutoff

 

 

 

Valve

 

 

Relief

 

 

 

Valve

Hot Water

 

 

Discharge

Drain

Cold

Line

Supply

Tube to

 

Outlet

suitable

Water

 

 

drain

Supply

 

 

 

Inlet

Notice: The above illustrates a pressure-only relief valve.. If local codes require a combination temperature and pressure relief valve be installed, an extension piece may be needed to ensure that the valve probe is not directly in the flow path of the water..

Relief Valve

A new pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22/ CSA 4.4, must be installed at the hot water outlet connection of the water heater at the time of installation. Local codes shall govern the installation of relief valves.

For safe operation of the water heater, be sure that:

The pressure rating of the relief valve must not exceed 150 psi (1034 kPa), the maximum working pressure of the water heater as marked on the rating plate..

The BTUH rating of the relief valve must equal or exceed the BTUH input of the water heater as marked on its rating plate..

No valve of any type should be installed between the relief valve and the water heater

Discharge from the relief valve should be piped to a suitable drain to eliminate potential water damage.. Piping used should be of a type approved for the distribution of hot water..

Hot and cold water lines should be insulated up to the water heater.. Refer to page 23 for details..

The discharge line must be NO SMALLER than the outlet of the relief valve and must pitch downward to allow complete drainage (by gravity) of the relief valve and discharge line..

The end of the discharge line should not be threaded or concealed and should be protected from freezing.. No valve of any type, restriction or reducer coupling should be installed in the discharge line..

Notice: Local codes govern the installation of relief valves.. If local codes require that a temperature and pressure relief valve should be installed, the manufacturer recommends a type 40XL Watts T&P relief valve or an equivalent model be used..

Notice: Manual operation of relief valves should be performed at least once a year.. Turn off the electrical power and gas shutoff valve.. Lift and release lever on the relief valve and check the manual operation of the relief valve.. You should take precaution to avoid contact with the hot water coming out of the relief valve and to prevent water damage..

Notice: If the relief valve on the system discharges periodically, a problem exists and service to the water system is required..

The vinyl tubing as shown is supplied and connects to the drain valve located at the hot water outlet as shown in the diagram at left.. Route the other end of the vinyl tubing to the drain pan or a suitable drain where leakage from the heater will not result in damage to the area adjacent to the heater or to lower floors of the structure..

17

Image 17
Contents Tankless Water Heater For Your Records Install and properly vent the water heater…  & # 0 Natural gas and liquefied petroleum models For Installations in the State of California Location of Water Heater Installing the water heaterInspect Shipment Corrosive AtmospheresVenting Lengths VentingDraining the Condensate Venting Through Closed SpacesAppliance Vent Adapter Horizontal Vent Terminal Location Canadian Installations US InstallationsAdditional Considerations Indoor Water HeaterHorizontal Vent Installation Vertical Vent Termination Location Vertical Vent InstallationWater Supply Connections Mounting the Water HeaterThermal Expansion Cold and hot water connections Lines.Air Drain Valve Shown on Right without Tubing Relief ValvePressure Testing the Gas Supply System Leak TestingGas Supply High AltitudeRemote Control Installation Projections Electrical Connection Power CordPer Foot Downward Pitch Typical Installation of Water Heater Venting RequiredInsulation Blankets Hot and Cold Pipe Insulation InstallationDuring Installation of this water heater… Indoor Water Heater Location Installation Check ListLighting the water heater Time/Temperature Relationship in Scalds Safety PrecautionsWater Temperature Setting Water Temperature Setting… Housekeeping Routine Preventative MaintenanceBurner Inspection Venting System InspectionVacation and Extended Shut-Down Condensate Trap InspectionFreeze Protection Draining the Water HeaterBefore You Call For Service… Error Code Guide Replacement Parts 135F 57C DIP If YOU Need Service