Rheem P), PH-25RDVS, RUTG-66DV, RMTG-66DV, ECO-180DV Draining the Water Heater, Freeze Protection

Page 30

Care and cleaning of the water heater:

 

Draining the Water Heater

 

Below are instructions for draining water out

 

of the water heater..

 

Turn off the switch on the remote control..

 

Close the gas shut-off valve(s)..

 

Unplug the power supply cord (or

 

disconnect breaker) at least 10 seconds

To Hot

after step #1..

Water

Open all hot water faucets.. Before

Faucet(s)

 

proceeding to the next step, make sure that

 

COLD water is coming out of all hot water

 

faucets..

 

Close the water shut-off valve..

 

Using a suitable container to catch water,

Drain Hose

remove the water filter from heater.. Attach

(To Suitable

a garden hose to the drain valve installed

Drain)

in the hot water outlet line and direct the

Draining the water heater

stream of water to a suitable drain where it will cause no damage.. Leave water heater as is until next use..

To put the water heater back into operation after draining, follow the steps below..

Reinstall the drain plug and water filter.. Close the hot water outlet drain valve..

Open the water shut-off valve and close again after making sure that water comes out from hot water faucets.. (This step is to remove air from the water lines..)

Plug into an electrical outlet, fully open the gas shut-off valve and the water shut-off valve..

NOTICE: The water heater may not operate unless the above procedure is followed correctly..

WARNING: Failure to follow these instructions while draining the water heater can cause serious damage to the water heater as well as personal injury, including scalding.

Optional Maintenance Method

Isolator valve kits may be purchased as optional items from manufacturer, distributor or place of purchase.. They allow for one person full

diagnostic testing and ease of flushing the system..

The kit includes two full port isolation valves, one for the cold side and one for the hot side..

CAUTION: Even when drained properly, a small amount of water will remain in the water heater. In cold weather, conditions this water can freeze. If this happens allow the defrost protection on the heater at least 30 minutes to melt the frozen water or the water heater may not work properly.

Hot Water Service Valve

Pressure Relief Valve

Drain

Water Outlet

 

Cold Water Service

Valve

Water Inlet

WARNING: Failure to drain the water heater can cause serious damage to the wate heater as well as pearsonal injury..

NOTICE: DO NOT unplug the electric power supply cord for freeze protection.

30

Freeze Protection

Where the water heater may be exposed to freezing conditions, even for a short period of time, be sure to drain all water from the unit as instructed above..

Exposure to freezing conditions can occur from down draft of venting system or from installation in areas exposed to cold air..

The water heater is equipped with a Freeze Protection Electric Heater.. As long as electricity is supplied to the water heater, it prevents freezing inside the water heater down to an ambient temperature of approximately

minus -30°F (-34°C) (without wind conditions)..

This device only protects the internal components of the water heater.. It does NOT

protect piping and valves.. Therefore, piping and valves should be wrapped with insulation material as instructed on page 23..

Another method of freeze prevention is by running a small volume of water.. Running water will protect the water heater, piping and valves..

Follow the steps below to ensure proper water flow through the water heater and piping:

Turn off the switch on the remote control..

Close the gas shut-off valve..

Open the hot water faucet slightly until a stream of approximately 1/8” (..32 cm) is flowing.. Be sure to check the flow periodically..

Image 30
Contents Tankless Water Heater For Your Records Install and properly vent the water heater…  & # 0 Natural gas and liquefied petroleum models For Installations in the State of California Installing the water heater Location of Water HeaterCorrosive Atmospheres Inspect ShipmentVenting Venting LengthsVenting Through Closed Spaces Appliance Vent AdapterDraining the Condensate Canadian Installations US Installations Horizontal Vent Terminal LocationIndoor Water Heater Additional ConsiderationsHorizontal Vent Installation Vertical Vent Installation Vertical Vent Termination LocationMounting the Water Heater Thermal ExpansionWater Supply Connections Cold and hot water connections Lines.Air Relief Valve Drain Valve Shown on Right without TubingGas Supply Leak TestingPressure Testing the Gas Supply System High AltitudeRemote Control Installation Projections Power Cord Electrical ConnectionTypical Installation of Water Heater Venting Required Per Foot Downward PitchHot and Cold Pipe Insulation Installation During Installation of this water heater…Insulation Blankets Installation Check List Indoor Water Heater LocationLighting the water heater Safety Precautions Water Temperature SettingTime/Temperature Relationship in Scalds Water Temperature Setting… Routine Preventative Maintenance HousekeepingVacation and Extended Shut-Down Venting System InspectionBurner Inspection Condensate Trap InspectionDraining the Water Heater Freeze ProtectionBefore You Call For Service… Error Code Guide Replacement Parts 135F 57C DIP If YOU Need Service