Vent Terminal | X Air Supply Inlet | Area Where Terminal is NOT Permitted |
Horizontal Vent Terminal Location |
|
The following information should be used for determining the proper location of the vent terminal for direct vent tankless water heaters..
|
| Canadian Installations 1 | US Installations 2 |
|
|
|
|
A= | Clearance above grade, veranda, | 12 inches (30 cm) above anticipated | 12 inches (30 cm) above anticipated |
| porch, deck or balcony.. | ||
| snow level.. | snow level.. | |
|
| ||
|
|
|
|
B= | Clearance to window or door that | 6 inches (15 cm) for appliances < 10,000 | 6 inches (15 cm) for appliances < |
| may be opened.. | ||
| 10,000 Btuh (3 kW), 9 inches (23 cm) | ||
|
| Btuh (3 kW), 12 inches (30 cm) for | |
|
| for appliances > 10,000 Btuh (3kW) | |
|
| appliances > 10,000 Btuh (3kW) and < | |
|
| and < 50,000 Btuh (15kW), 12 inches | |
|
| 100,000 Btuh (30kW), 36 inches (91 cm) | |
|
| (30 cm) for appliances > 50,000 Btuh | |
|
| for appliances > 100,000 Btuh (30kW).. | |
|
| (15kW).. | |
|
|
| |
|
|
|
|
C= | Clearance to permanently closed | * | * |
| window.. | ||
|
|
|
|
D= | Vertical Clearance to ventilated |
|
|
| soffit located above the terminal |
|
|
| within a horizontal distance of 2 | * | * |
| feet (61 cm) from the center line of | ||
|
|
| |
| the terminal.. |
|
|
|
|
|
|
E= | Clearance to unventilated soffit.. | * | * |
|
| ||
|
|
|
|
F= | Clearance to outside corner.. | * | * |
|
| ||
|
|
|
|
G= | Clearance to corner.. | * | * |
|
| ||
|
|
| |
|
|
|
|
H = Clearance to each side of center line | 3 feet (91 cm) within a height 15 feet |
| |
| extended meter/regulator assembly.. |
| |
| (4..57 m) above the meter/regulator | * | |
| above | ||
| assembly.. |
| |
|
|
| |
|
|
|
|
I = | Clearance to service regulator | 3 feet (91 cm) | * |
| coaxial vent outlet.. | ||
|
|
| |
|
|
|
|
J = | Clearance to nonmechanical air | 6 inches (15 cm) for appliances < | 6 inches (15 cm) for appliances < 10,000 |
| supply inlet to the combustion | 10,000 Btuh (3 kW), 12 inches (30 cm) | |
| air inlet to any building or other | for appliances > 10,000 Btuh (3kW) | Btuh (3 kW), 9 inches (23 cm) for |
| appliances > 10,000 Btuh (3kW) and < | ||
| appliance.. | and < 100,000 Btuh (30kW), 36 inches | |
| 50,000 Btuh (15kW), 12 inches (30 cm) | ||
|
| (91 cm) for appliances > 100,000 Btuh | |
|
| for appliances > 50,000 Btuh (15kW).. | |
|
| (30kW).. | |
|
|
| |
|
|
|
|
K = | Clearance to mechanical air supply | 6 feet (1..83 m) | 3 feet (91 cm) above if within 10 feet |
| inlet.. | (3 m) horizontally.. | |
|
| ||
|
|
| |
|
|
|
|
L = | Clearance above paved sidewalk or |
|
|
| paved driveway located on public | 7 feet (2..13 m)† | * |
| property.. |
|
|
|
|
| |
M = Clearance under veranda, porch, | Not Allowed | Not Allowed | |
| deck or balcony.. | ||
|
|
|
1In accordance with current
2In accordance with current ANSI Z223..1/ NFPA 54 National Fuel Gas Code..
†A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family
dwellings and serves both dwellings..
* For clearances not specified in ANSI 223..1/NFPA 54 or |
| |
a) | A minmum clearance value determined by testing in accordance with section 2..20, or; |
|
b) | A reference to the following footnote: "Clearance in accordance with local installtion codes and the require- | 11 |
| ments of the gas supplier.." |