GE GN94DNSRSA Clearances for Water Heater, Corrosive Atmospheres, Mounting the Water Heater

Page 10

Installation Instructions

CLEARANCES FOR WATER HEATER

WARNING: Combustible construction refers to adjacent walls and ceiling and should not be confused with combustible or flammable products and materials. Combustible and/or flammable products and materials should never be stored in the vicinity of this or any gas appliance.

To top

To side

To floor/ground To front

 

To combustibles

To noncombustibles

Top of heater

6 inches (152 mm)

2 inches (51 mm)

Back of heater

0 (zero)

0 (zero)

Front of heater

6 inches (152 mm)

6 inches (152 mm)

Sides of heater

2 inches (51 mm)

1/8 inch (3 mm)

Floor/ground

12 inches (305 mm)

12 inches (305 mm)

Vent

0 (zero)

0 (zero)

Closet

6 inches (152 mm)

6 inches (152 mm)

 

from front

from front

*Every vent connection must be accessible for inspection, cleaning and replacement.

CORROSIVE ATMOSPHERES

NOTICE: The water heater or intake air supply should not be installed near an air supply containing halogenated hydrocarbons

or near swimming pool chemicals.

MOUNTING THE WATER HEATER

CAUTION: Reinforcement of the wall is required in case the wall is not strong enough to hold the water heater. Do not mount to drywall unless mounting screws are secured in wall studs.

Make sure the location of the water heater allows for easy access and operation.

Wall studs should be utilized when mounting the water heater to the wall. On masonry or concrete wall, use concrete anchors or lag bolts.

1Identify the installation location and confirm that the installation will meet all required clearances. Use mounting template

to locate screw and anchor locations.

2Securely attach the water heater to the wall using the brackets located at the top and bottom of the water heater.

3Ensure that the attachment strength is sufficient to support the weight. Refer to the weight of the water heater in the Specification Guidelines. Four mounting screws with 200 lb. tensile load capability are required at

a minimum.

Wall installation brackets

10

Image 10
Contents For Your Safety Before BeginninginstallationSafety Precautions Models GN75DNSRSA, GN94DNSRSA, GP94DNSRSAInstallation Instructions Safety PrecautionsParts Provided Tools YOU will NeedGN75/GN94/GP94DNSRSA DimensionsDescription Planning for Venting INTAKE/EXHAUST GuidelinesFlue Terminal Clearances Flue Terminal Clearances Ansi Z21.10.3 CSAAdditional Clearances Vent Terminal Horizontal Termination with Flue Installation Condensate DrainCondensate Drain Planning for Plumbing Shown with optional pipe coverCorrosive Atmospheres Clearances for Water HeaterMounting the Water Heater Mounting the Water Heater Mounting the WaterheaterGAS Piping GAS PipingConnecting the Water Heater to the GAS Supply Pressure Relief Valve Water PipingWater Piping Internal BUILT-IN Freezer ProtectionConnecting the Water Heater to the Water Supply Supplemental Freeze ProtectionRecommended Piping for Basic Installation KEYFreeze Protection For External Piping Electrical Connection Information Electrical RequirementsCondensate Venting InstructionsVenting Instructions Maximum Vent LengthVent Products Flue Installation Concentric VentingProduct Parts High Altitude Installations GuidelinesLocation Remote Controller InstallationConfigurations Mounting the ControllerCleaning the Inlet Filter Cleaning the Inlet FilterInstallation Checklist Pressure Drop Curve Technical DataOutlet Flow Data Ladder Diagram Page