Installation Instructions
MOUNTING THE WATERHEATER (cont.)
4FINISHED WALLS (Drywall) Option 1:
Mount boards over drywall directlyto studs in the wall.When attachingthe unit to a finished wall, mount two boards suitablefor anchoring to wall studs. Levelthe unit duringinstallation.
NOTE: Do not hang the unit on drywallonly. The unit must be secured into woodmounting board.
243⁄4″
Boardson outsideof finishedwall
FINISHED WALLS (Drywall) Option 2: Framed wall with boards behind the drywall. Mount the unit to boards in the wall. Do not use the screws providedto mount through drywall. Screws long enough to penetrate the drywall and provide at least 1″ of engagement in wood shouldbe used. Screws should be ratedto carry
atensile load of 200 lbs each. Levelthe unit duringinstallation.
243⁄4″ |
Boardson insideof finishedwall
NOTES:
•Screws providedmust fastensecurely
and directly into wood. If screwsgo through drywall and do not fullyengage the wood stud, the installer must supply correct screws.
•Do not hang the unit on drywallonly. The unit must be secured into woodmounting board.
MOUNTING THE WATER HEATER (cont.)
ON MASONRY OR CEMENT WALL: Mount
4 wall anchors (not supplied) in a wall suitable to carry 200 lbs minimum tensile load each. Level the unit during installation.
IMPORTANT: Anchors suitable for masonry or concrete are to be supplied by the installer.