Desa GMP26T, GMP20BT, GMP16T, GMP30BT Thermostat Controlled Models Lighting Instructions

Page 16

OPERATING HEATER

Continued

THERMOSTAT CONTROLLED

MODELS

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 21).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop up when re- leased, contact a qualified service person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the igni- tor button (see Figure 21). This will light pilot. If necessary, continue to press igni- tor button until pilot lights.

If pilot does not light

turn thermostat control knob clockwise Clockwise to the OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, page 20.

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 17.

Ignitor Button

Control Knob

 

FO

7.Keep control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when re- leased, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The main burner should light. Set control knob to any heat level between 1 and 5.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Thermocouple

Ignitor Electrode

Pilot Burner

Figure 22 - Pilot (actual pilot may vary)

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PI- LOT position.

Figure 21 - Control Knob In The OFF

Position

16

www.desatech.com

113048-01C

Image 16
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Identification Local CodesAIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Locating HeaterInstalling Heater to Wall Attaching To Wall Anchor Method 20,000 Btu/Hr ModelsPlacing Heater On Mounting Bracket Installing Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing GAS Supply Piping System Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Pressure Testing Heater GAS ConnectionsOperating Heater Manual Control Models Lighting InstructionsTo Select Heating Level for Infrared Heaters Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Controlled Models Lighting Instructions Inspecting Heater Thermostat Control OperationPilot Flame Pattern Control Knob GMP16TBurner Flame Pattern for Blue Flame Heaters Inpecting HeaterBurner Flame Pattern for Infrared Heaters Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyPressed See Cleaning and Mainte Gas leak. See Warning Statement aboveGMP30BT GMP20BT SpecificationsGMP16 GMP26 GMP16T GMP26T Service Hints Technical ServiceService Publications Replacement Parts AccessoriesIllustrated Parts Breakdown Models GMP16, GMP26, GMP16T, and GMP26TParts List Parts AVAILABLE-NOT ShownIllustrated Parts Breakdown and Parts List Models GMP16 and GMP26ODS/Pilot Burner Assembly GMP16T Models GMP16T and GMP26TModels GMP20BT and GMP30BT Parts Available not Shown Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Residential GAS Heaters