INSTALLATION
Continued
THERMOSTAT SENSING BULB (Thermostat Models Only)
The thermostat sensing bulb has been placed be- low the heater.
1.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hard- ware package.
2.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the ther- mostat sensing bulb is pointing up.
Clamp
Thermostat
Sensing Bulb
Figure 5 - Attaching Thermostat Sensing
Bulb
INSTALLING HEATER TO WALL
Mounting Bracket
Locate mounting bracket in heater carton. Remove mounting bracket from heater carton.
Figure 6 - Mounting Bracket
Removing Front Panel Of Heater
1.Remove the four painted screws, two on each side of front panel.
2.Pull bottom of front panel forward, then out.
3.Remove any remaining packaging materials.
Figure 7 - Removing Front Panel Of
Heater
Methods For Attaching Mounting Bracket To Wall
Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14 inches apart from their centers. Attach mounting bracket to wall in one of two ways:
1.Attaching to wall stud
2.Attaching to wall anchor
Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.
Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).
Decide which method better suits your needs. Ei- ther method will provide a secure hold for the mounting bracket.
Marking Screw Locations
1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.
WARNING: Maintain mini- mum clearances shown in Fig- ure 8, page 10. If you can, provide greater clearances from floor and joining wall.
www.desatech.com | 9 |