Desa GMP26T, GMP20BT, GMP16T AIR for Combustion Ventilation, Providing Adequate Ventilation

Page 5

AIR FOR COMBUSTION

AND VENTILATION

WARNING: This heater shall not be installed in a confined space or unusually tight con- struction unless provisions are provided for adequate combus- tion and ventilation air. Read the following instructions to in- sure proper fresh air for this and other fuel-burning appli- ances in your home.

Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During heating months, home owners want their homes as airtight as possible.

While it is good to make your home energy effi- cient, your home needs to breathe. Fresh air must enter your home. All fuel-burning appliances need fresh air for proper combustion and ventilation.

Exhaust fans, fireplaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.

PROVIDING ADEQUATE

VENTILATION

The following are excerpts from National Fuel Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation.

All spaces in homes fall into one of the three fol- lowing ventilation classifications:

1.Unusually Tight Construction

2.Unconfined Space

3.Confined Space

The information on pages 5 through76 will help you classify your space and provide adequate ventilation.

Unusually Tight Construction

The air that leaks around doors and win- dows may provide enough fresh air for combustion and ventilation. However, in buildings of unusually tight construction, you must provide additional fresh air.

Unusually tight construction is defined as construction where:

a.walls and ceilings exposed to the out- side atmosphere have a continuous water vapor retarder with a rating of one perm (6x10-11kg per pa-sec-m2) or less with openings gasketed or sealed and

b.weather stripping has been added on openable windows and doors and

c.caulking or sealants are applied to ar- eas such as joints around window and door frames, between sole plates and floors, between wall-ceiling joints, be- tween wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.

If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 7.

If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Location, page 6.

Confined and Unconfined Space

The National Fuel Gas Code, ANSI Z223.1/NFPA 54 defines a confined space as a space whose vol- ume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space and an un- confined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all ap- pliances installed in that space. Rooms communi- cating directly with the space in which the appli- ances are installed*, through openings not fur- nished with doors, are considered a part of the unconfined space.

*Adjoining rooms are communicating only if there are doorless passageways or ventilation grills be- tween them.

113048-01C

www.desatech.com

5

Image 5
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Safety Information Product IdentificationProviding Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationCheck GAS Type Ventilation Air From Inside BuildingLocating Heater Installation ItemsInstalling Heater to Wall Placing Heater On Mounting Bracket 20,000 Btu/Hr ModelsAttaching To Wall Anchor Method Mounting Base Feet to Floor Where required by local code Installing Bottom Mounting ScrewsMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterTypical Inlet Pipe Diameters Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Heater GAS Connections For Your Safety Read Before LightingOperating Heater Manual Control Models Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureTo Select Heating Level for Infrared Heaters Thermostat Controlled Models Lighting Instructions Thermostat Control Operation Inspecting HeaterPilot Flame Pattern Control Knob GMP16TBurner Flame Pattern for Infrared Heaters Inpecting HeaterBurner Flame Pattern for Blue Flame Heaters ODS/PILOT and Burner Cleaning MaintenanceBurner Pilot AIR Inlet CabinetObserved Problem Possible Cause Remedy TroubleshootingPressed See Cleaning and Mainte Statement above Gas leak. See WarningGMP16 GMP26 GMP16T GMP26T SpecificationsGMP30BT GMP20BT Technical Service Service HintsService Publications Replacement Parts AccessoriesModels GMP16, GMP26, GMP16T, and GMP26T Illustrated Parts BreakdownParts AVAILABLE-NOT Shown Parts ListModels GMP16 and GMP26 Illustrated Parts Breakdown and Parts ListModels GMP16T and GMP26T ODS/Pilot Burner Assembly GMP16TModels GMP20BT and GMP30BT Parts Available not Shown Limited Warranty VENT-FREE Residential GAS Heaters Warranty InformationKeep this Warranty