ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

MODELS GMP16T AND GMP26T

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions

listed under Replacement Parts on page 25 of this manual.

1

2

1

5

6

2

7

3

4

ODS/Pilot

5

Burner Assembly GMP16T

1

6

2

7

6

 

 

 

3

 

 

 

 

 

 

4

 

 

 

 

Burner Assembly GMP26T

 

 

 

 

 

 

KEY

PART NUMBER

 

 

 

NO.

GMP16T

GMP26T

DESCRIPTION

QTY.

 

 

 

 

 

 

 

1

110803-02*

110803-02*

ODS/Pilot

1

 

2

110186-01

110186-01

Thermocouple Kit

1

 

3

099387-11

099387-03

Pilot Tubing

1

 

4

104818-03

104818-04

Outlet Tubing

1

 

5

099218-08

099218-09

Burner

1

 

6

099056-25

099056-25

Injector - Plaque A or C

1-2

 

7

099056-01

099056-01

Injector - Plaque B

1

 

 

 

 

 

 

 

*If replacing ODS pilot and your model is pre 2002, your part number will be 103894-04.The thermocouple part number will be 098514-01. The electrode part number will be 098594-01.

113048-01C

www.desatech.com

29

Image 29
Contents What to do if YOU Smell GAS Table of Contents Safety Information Local Codes Safety Information Product IdentificationProviding Adequate Ventilation AIR for Combustion VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR InstallationCheck GAS Type Ventilation Air From Inside BuildingLocating Heater Installation ItemsInstalling Heater to Wall Placing Heater On Mounting Bracket 20,000 Btu/Hr ModelsAttaching To Wall Anchor Method Mounting Base Feet to Floor Where required by local code Installing Bottom Mounting ScrewsMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterTypical Inlet Pipe Diameters Connecting to GAS SupplyChecking GAS Connections Pressure Testing GAS Supply Piping SystemTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Heater GAS Connections For Your Safety Read Before LightingOperating Heater Manual Control Models Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureTo Select Heating Level for Infrared Heaters Thermostat Controlled Models Lighting Instructions Thermostat Control Operation Inspecting HeaterPilot Flame Pattern Control Knob GMP16TBurner Flame Pattern for Infrared Heaters Inpecting HeaterBurner Flame Pattern for Blue Flame Heaters ODS/PILOT and Burner Cleaning MaintenanceBurner Pilot AIR Inlet CabinetObserved Problem Possible Cause Remedy TroubleshootingPressed See Cleaning and Mainte Statement above Gas leak. See WarningGMP16 GMP26 GMP16T GMP26T SpecificationsGMP30BT GMP20BT Technical Service Service HintsService Publications Replacement Parts AccessoriesModels GMP16, GMP26, GMP16T, and GMP26T Illustrated Parts BreakdownParts AVAILABLE-NOT Shown Parts ListModels GMP16 and GMP26 Illustrated Parts Breakdown and Parts ListModels GMP16T and GMP26T ODS/Pilot Burner Assembly GMP16TModels GMP20BT and GMP30BT Parts Available not Shown Limited Warranty VENT-FREE Residential GAS Heaters Warranty InformationKeep this Warranty