Desa GMP26T, GMP20BT Specifications, GMP30BT GMP20BT, GMP16 GMP26 GMP16T GMP26T

Page 24

SPECIFICATIONS

 

GMP30BT

GMP20BT

Btu (Variable)

15,000/30,000

10,000/20,000

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (in. of water)

 

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

 

Heater (Includes knobs & grill)

24 1/4 x 25 3/4 x 7

24 1/4 x 18 1/4 x 7

Carton

26 3/8 x 28 1/8 x 10

26 3/8 x 20 7/8 x 10

Weight (pounds)

 

 

Heater

28

20

Shipping

33

25

 

GMP16

GMP26

 

GMP16T

GMP26T

Btu (Variable)

6,000/11,000/16,000

6,000/16,000/26,000

Type Gas

Propane/LP Only

Propane/LP Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure* (in. of water)

 

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

 

Heater

24 1/4 x 18 1/4 x 7

24 1/4 x 25 3/4 x 7

Carton

26 3/8 x 20 7/8 x 10

26 3/8 x 28 1/8 x 10

Weight (pounds)

 

 

Heater

20

28

Shipping

25

33

Note: Dimensions listed are outer most pointson the heater (includes control knobs and grill). * For purposes of input adjustment.

24

www.desatech.com

113048-01C

Image 24
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Identification Local CodesAIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Locating HeaterInstalling Heater to Wall 20,000 Btu/Hr Models Attaching To Wall Anchor MethodPlacing Heater On Mounting Bracket Installing Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing GAS Supply Piping System Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Pressure Testing Heater GAS ConnectionsOperating Heater Manual Control Models Lighting InstructionsManual Lighting Procedure To Select Heating Level for Infrared HeatersTo Turn OFF GAS To Appliance Thermostat Controlled Models Lighting Instructions Inspecting Heater Thermostat Control OperationPilot Flame Pattern Control Knob GMP16TInpecting Heater Burner Flame Pattern for Blue Flame HeatersBurner Flame Pattern for Infrared Heaters Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyPressed See Cleaning and Mainte Gas leak. See Warning Statement aboveSpecifications GMP30BT GMP20BTGMP16 GMP26 GMP16T GMP26T Service Hints Technical ServiceService Publications Replacement Parts AccessoriesIllustrated Parts Breakdown Models GMP16, GMP26, GMP16T, and GMP26TParts List Parts AVAILABLE-NOT ShownIllustrated Parts Breakdown and Parts List Models GMP16 and GMP26ODS/Pilot Burner Assembly GMP16T Models GMP16T and GMP26TModels GMP20BT and GMP30BT Parts Available not Shown Warranty Information Keep this WarrantyLimited Warranty VENT-FREE Residential GAS Heaters