Desa GMP26T, GMP20BT Illustrated Parts Breakdown and Parts List, Models GMP16 and GMP26

Page 28

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

MODELS GMP16 AND GMP26

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 25 of this manual.

13

7

1 2

5

6

3

8

11

1

2

410

9

4

 

7

 

1

2

 

 

Burner Assembly GMP16

 

8

 

 

 

 

11

 

 

10

ODS/Pilot

5

6

7

3

 

4

12

10

12

13

9

Burner Assembly

GMP26

4

KEY

PART NUMBER

 

 

NO.

GMP16

GMP26

DESCRIPTION

QTY.

 

 

 

 

 

1

110803-02*

110803-02*

ODS/Pilot

1

2

110186-01

110186-01

Thermocouple Kit

1

3

098200-03

098200-03

Control Valve Bracket

1

4

105051-01

105050-02

Pilot Tubing

1

5

099218-08

099218-09

Burner

1

6

098508-01

098508-01

Valve Retainer Nut

1

7

099056-25

099056-25

Injector - Plaque A or C

1-2

8

099056-01

099056-01

Injector - Plaque B

1

9

103844-01

100747-01

Control Valve

1

10

103352-03

103353-04

Tubing-Valve to Plaque A

1

11

103352-04

103353-05

Tubing-Valve to Plaque B

1

12

_____

103353-06

Tubing-Valve to Plaque C

1

13

107660-01

107660-03

Inlet Tube

1

 

 

 

 

 

*If replacing ODS pilot and your model is pre 2002, your part number will be 103894-04. The thermocouple part number will be 098514-01. The electrode part number will be 098594-01.

28

www.desatech.com

113048-01C

Image 28
Contents What to do if YOU Smell GAS Table of Contents Safety Information Safety Information Product Identification Local CodesAIR for Combustion Ventilation Providing Adequate VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceInstallation Ventilation AIRCheck GAS Type Ventilation Air From Inside BuildingInstallation Items Locating HeaterInstalling Heater to Wall Attaching To Wall Anchor Method 20,000 Btu/Hr ModelsPlacing Heater On Mounting Bracket Installing Bottom Mounting Screws Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor with Optional Floor KIT Mounting Base Feet to HeaterConnecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing GAS Supply Piping System Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Pressure Testing Heater GAS ConnectionsOperating Heater Manual Control Models Lighting InstructionsTo Select Heating Level for Infrared Heaters Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Controlled Models Lighting Instructions Inspecting Heater Thermostat Control OperationPilot Flame Pattern Control Knob GMP16TBurner Flame Pattern for Blue Flame Heaters Inpecting HeaterBurner Flame Pattern for Infrared Heaters Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyPressed See Cleaning and Mainte Gas leak. See Warning Statement aboveGMP30BT GMP20BT SpecificationsGMP16 GMP26 GMP16T GMP26T Service Hints Technical ServiceService Publications Replacement Parts AccessoriesIllustrated Parts Breakdown Models GMP16, GMP26, GMP16T, and GMP26TParts List Parts AVAILABLE-NOT ShownIllustrated Parts Breakdown and Parts List Models GMP16 and GMP26ODS/Pilot Burner Assembly GMP16T Models GMP16T and GMP26TModels GMP20BT and GMP30BT Parts Available not Shown Keep this Warranty Warranty InformationLimited Warranty VENT-FREE Residential GAS Heaters