Desa CGB50P, CGB35P installation manual Illustrated Parts List

Page 36

ILLUSTRATED

 

 

 

 

PARTS LIST

 

 

 

 

 

Burner

 

 

 

 

Assembly

 

 

 

 

 

 

1

 

 

 

 

 

 

3

 

 

 

 

 

2

 

 

 

 

 

4

 

 

 

7

 

50 Model

11

 

 

 

27

 

 

 

 

23

 

 

6

 

 

 

7

 

 

 

 

 

 

35 Model

7

 

 

 

 

25

 

 

 

6

 

 

 

 

 

8

 

 

 

 

 

 

 

 

5

 

 

 

22

 

10

 

 

 

 

 

 

 

 

 

 

 

11

 

26

 

28

9

 

 

24

13

 

 

 

 

 

 

 

 

 

12

 

24-1

24-3

 

 

 

19

 

14

 

24-2

24-4

 

 

21

 

 

 

 

 

15

 

 

 

17

20

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

4

 

16

 

 

 

 

 

 

 

 

 

 

17

 

 

36

 

 

 

 

 

 

 

 

 

 

100352

Image 36
Contents OWNER’S Operation and Installation Manual For Your SafetyWhat to do if YOU Smell GAS Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product Identification Local Codes Unpacking Product Features Installation ItemsCheck GAS Type Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply External Regulator with Vent Pointing DownGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Glass Panel Removing Lower Front Access PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area For Your Safety Read Before Lighting Operating HeaterLighting Instructions Viewing Pilot Manual Lighting Procedure To Turn OFF GAS to ApplianceShutting Off Heater Shutting Off Burner Only pilot stays litInspecting Pilot and Burner Flame Pilot Flame PatternBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyObserved Possible Remedy Problem Cause TROUBLE- ShootingStat bulb satisfied Gas leak. See Warning Statement at topService Procedures Removing Control Valve and Burner TubeRemoving Burner Changing Burner Orifice Orifice Location 35,000 BTU/Hr Burner ShownTechnical Service Service Hints35,000 BTU/Hr ModelOrdering Replacement Parts Centrals Parts Under WarrantyParts Not Under Warranty Accessories Valve GA5010Illustrated Parts List QTY Cabinet Assembly 100352 Warranty Information International