Desa CGB35P, CGB50P installation manual Qty

Page 37

PARTS LIST

Burner

Assembly

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 34 of this manual.

KEY

PART NUMBER FOR

 

NO.

CGB50P

CGB35P

DESCRIPTION

1

100206-02

100206-01

Combustion Chamber

2

098324-02

098324-02

Control Knob

3

097159-02

097159-02

Piezo Ignitor

4

098271-05

098271-05

Ignitor Cable

5

099974-02

099974-01

Control Rod

6

099704-05

063015

Limit Switch Bracket Kit

7

——

M11084-26

Screw, #10-16 x 3/8"

 

M11084-26

——

Screw, #10-16 x 3/8"

8

099986-01

099986-01

Thermocouple Wire Assembly

9

100000-01

100000-01

Cotter Pin

10

231939

231940

Limit Switch

11

M11084-38

——

Screw, #8-18 x 3/8"

 

——

M11084-38

Screw, #8-18 x 3/8"

12

099211-01

099211-01

Screw, #10-16 x 2 1/2"

13

100207-02

100207-02

Control Valve

14

098265-01

098265-01

Elbow

15

098936-02

098936-02

Thermocouple Interrupter

16

100028-02

100028-02

Pilot Tubing

17

100307-01

100307-01

Thermocouple

18

099976-02

099976-02

Burner Tube

19

530988

530988

Control Bracket

20

100309-01

100309-01

Orifice Holder

21

530124

100469-01

Orifice

22

100385-01

100384-01

Burner Assembly

23

100090-01

100090-01

Burner Bracket

24

100308-02

100308-02

Pilot Assembly

24-1

100467-01

100467-01

Pilot Sleeve

24-2

100466-01

100466-01

Pilot Nut

24-3

100468-01

100468-01

Pilot Electrode

24-4

100465-01

100465-01

Nut Electrode

25

101342-05

101342-04

Glass Panel Package

 

 

 

(includes bottom glass retainer)

26

098249-01

098249-01

Nut, M5 x 0.8

27

530192

530192

Glass Spring

28

098304-01

098304-01

Screw, #10-24 x 3/8"

 

 

 

 

 

 

 

 

QTY.

1

1

1

1

1

1

3

2

1

1

1

3

2

2

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

3

37

100352

Image 37
Contents For Your Safety OWNER’S Operation and Installation ManualWhat to do if YOU Smell GAS Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Product Identification Installation Items Local Codes Unpacking Product FeaturesCheck GAS Type Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent External Regulator with Vent Pointing Down Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemRemoving Lower Front Access Panel Installing Glass PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Operating Heater For Your Safety Read Before LightingLighting Instructions Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litPilot Flame Pattern Inspecting Pilot and Burner FlameBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Observed Possible Remedy Problem CauseStat bulb satisfied Statement at top Gas leak. See WarningRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Orifice Location 35,000 BTU/Hr Burner Shown Changing Burner OrificeService Hints Technical Service35,000 BTU/Hr ModelParts Under Warranty Ordering Replacement Parts CentralsParts Not Under Warranty Valve GA5010 AccessoriesIllustrated Parts List QTY Cabinet Assembly 100352 International Warranty Information