Desa CGB50P, CGB35P installation manual Trouble Shooting, Observed Possible Problem Cause Remedy

Page 26

TROUBLE-

SHOOTING

Note: All troubleshooting items are listed in order of operation.

26

WARNING

Turn off and unplug heater and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting system.

CAUTION

Never use a wire, needle, or similar object to clean pilot. This can damage pilot.

OBSERVED

POSSIBLE

 

 

 

 

PROBLEM

CAUSE

REMEDY

 

 

 

 

 

 

 

When ignitor button is

1.

Incorrect spark gap.

1.

Adjust spark gap to 1/16".

pressed, there is no

2.

Ignitor electrode posi-

2.

Replace ignitor.

 

spark at pilot.

 

tioned wrong.

 

 

 

 

 

3.

Ignitor electrode broken.

3.

Replace ignitor.

 

 

4.

Ignitor electrode not con-

4.

Reconnect ignitor cable.

 

 

nected to ignitor cable.

 

 

 

 

 

5.

Ignitor cable pinched or

5.

Free ignitor cable if

 

 

wet.

 

pinched by any metal or

 

 

 

 

tubing.

Keep

ignitor

 

 

 

 

cable dry.

 

 

6.

Piezo ignitor nut is loose.

6.

Tighten nut holding piezo

 

 

 

 

ignitor to heater cabinet.

 

 

 

 

Nut is located

inside

 

 

 

 

heater cabinet at top.

 

7.

Broken or frayed ignitor

7.

Replace ignitor cable.

 

 

cable.

 

 

 

 

 

8.

Loose ignitor cable.

8.

Reconnect ignitor cable.

 

9.

Bad piezo ignitor.

9.

Replace piezo ignitor.

 

 

 

 

When ignitor button is

1. Gas supply turned off or

1.

Turn on gas supply or

pressed, there is spark

 

manual shutoff valve

 

open manual

shutoff

at pilot but no igni-

 

closed.

 

valve.

 

 

tion.

2.

Control knob not in PI-

2.

Turn control knob to PI-

 

 

LOT position.

 

LOT position.

 

 

3.

Control knob not pressed

3.

Press in

control knob

 

 

in while in PILOT posi-

 

while in PILOT position.

 

 

tion.

 

 

 

 

 

4.

Air in gas lines when in-

4.

Continue

holding down

 

 

stalled.

 

control knob. Repeat ig-

 

 

 

 

niting operation until air

 

 

 

 

is removed.

 

 

5.

Depleted gas supply.

5.

Contact local propane gas

 

 

 

 

company.

 

 

 

6.

Pilot is clogged.

6.

Clean pilot (see Cleaning

 

 

 

 

and Maintenance, page

 

 

 

 

25) or replace pilot as-

 

 

 

 

sembly.

 

 

 

7.

Gas regulator setting is

7.

Replace control valve.

 

 

not correct.

 

 

 

 

100352

Image 26
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product Identification Check GAS Type Local Codes Unpacking Product FeaturesInstallation Items Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply External Regulator with Vent Pointing DownGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Glass Panel Removing Lower Front Access PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burner Only pilot stays litBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyObserved Possible Remedy Problem Cause TROUBLE- ShootingStat bulb satisfied Gas leak. See Warning Statement at topService Procedures Removing Control Valve and Burner TubeRemoving Burner Changing Burner Orifice Orifice Location 35,000 BTU/Hr Burner Shown35,000 BTU/Hr Technical ServiceService Hints ModelParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Accessories Valve GA5010Illustrated Parts List QTY Cabinet Assembly 100352 Warranty Information International