Desa CGB35P, CGB50P installation manual Technical Service, Service Hints, 35,000 BTU/Hr, Model

Page 33

TECHNICAL

SERVICE

SPECIFICATIONS

SERVICE

HINTS

You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190.

 

35,000 BTU/Hr

50,000 BTU/Hr

 

Model

Model

BTU

35,000

50,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

10.5" W.C.

10.5" W.C.

Inlet Gas Pressure

 

 

Maximum

14" W.C.

14" W.C.

Minimum

11" W.C.

11" W.C.

Dimensions, Inches

 

 

Heater (H x W x D)

25 x 27 1/4 x 16

28 x 32 1/2 x 16

Shipping Weight (pounds)

78

98

Flue Vent Size

4" dia.

4" dia.

Orifice Size

52 drill, ø .0635

46 drill, ø .081

Note: These heaters are certified for elevations of 0-4500 feet above sea level. For elevations above 2000 feet, de-rate heater 4% for each 1000 feet above sea level.

When gas pressure is too low

pilot will not stay lit

burner will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner will produce yellow flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

33

100352

Image 33
Contents OWNER’S Operation and Installation Manual For Your SafetyWhat to do if YOU Smell GAS Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Product Identification Local Codes Unpacking Product Features Installation ItemsCheck GAS Type Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent External Regulator with Vent Pointing Down Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemRemoving Lower Front Access Panel Installing Glass PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area For Your Safety Read Before Lighting Operating HeaterLighting Instructions Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litInspecting Pilot and Burner Flame Pilot Flame PatternBurner Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Observed Possible Remedy Problem CauseStat bulb satisfied Statement at top Gas leak. See WarningRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Orifice Location 35,000 BTU/Hr Burner Shown Changing Burner OrificeService Hints Technical Service35,000 BTU/Hr ModelOrdering Replacement Parts Centrals Parts Under WarrantyParts Not Under Warranty Valve GA5010 AccessoriesIllustrated Parts List QTY Cabinet Assembly 100352 International Warranty Information