Desa CGB35P, CGB50P installation manual Gas leak. See Warning, Statement at top

Page 29

TROUBLE- SHOOTING

Continued

WARNING

If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

 

REMEDY

 

 

 

 

 

 

Heater produces a

1.

Metal expanding

while

1.

This is common with

clicking/ticking noise

 

heating or contracting

 

most heaters. If noise is

just after burner is lit

 

while cooling.

 

 

excessive, contact quali-

or shut off.

 

 

 

 

fied service person.

 

 

 

 

 

 

Heater produces un-

1.

Heater burning

vapors

1.

Ventilate room. Stop us-

wanted odors.

 

from paint, hair

spray,

 

ing odor causing products

 

 

glues, etc.

 

 

while heater is running.

 

2.

Low fuel supply.

 

2.

Refill supply tank.

 

3.

Gas leak. See Warning

3.

Find and correct all leaks

 

 

statement at top of

 

(see Checking Gas Con-

 

 

page.

 

 

nections, page 13).

 

 

 

 

 

 

Heater shuts off in use. 1. Heater not venting correctly. Vent safety switch shuts off heater.

2. Low line pressure.

3. Pilot partially clogged.

1.Check venting system. If damaged or blocked, re- pair. If venting system is OK, have qualified ser- vice person replace vent safety switch, wire har- ness, or thermocouple in- terrupter.

2.Contact local propane gas company.

3.Clean pilot (see Cleaning and Maintenance, page 25).

Gas odor even when

1. Gas leak. See Warning

1.

Find and correct all leaks

control knob is in OFF

 

statement at top of

 

(see Checking Gas Con-

position.

 

page.

 

nections, page 13).

 

 

2.

Control valve damaged.

2.

Replace control valve.

 

 

 

 

 

 

Gas odor during com-

1. Foreign matter between

1.

Take apart gas tubing and

bustion.

 

control valve and burner.

 

remove foreign matter.

 

 

2.

Gas leak. See Warning

2.

Find and correct all leaks

 

 

 

statement at top of

 

(see Checking Gas Con-

 

 

 

page.

 

nections, page 13).

 

 

3.

Foreign fumes in area of

3.

Ventilate area around

 

 

 

heater being drawn

 

heater to remove any for-

 

 

 

through burner combus-

 

eign fumes.

 

 

 

tion.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

100352

Image 29
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Carbon monoxide poisoning may lead to death Safety InformationSafety Information Product Identification Check GAS Type Local Codes Unpacking Product FeaturesInstallation Items Heater Clearances Locating HeaterVenting Heater Do not vent heater in any of the following ways see Figure Venting HeaterVenting Heater Proper Size Vent External Regulator with Vent Pointing Down Connecting to GAS SupplyGas Connection Checking GAS Connections Pressure Testing Gas Supply Piping SystemRemoving Lower Front Access Panel Installing Glass PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Draft Hood Spillage Test Determining FRESH-AIR Flow for Heater LocationVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot To Turn OFF GAS to Appliance Manual Lighting ProcedureShutting Off Heater Shutting Off Burner Only pilot stays litBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Observed Possible Problem Cause Remedy Trouble ShootingTROUBLE- Shooting Observed Possible Remedy Problem CauseStat bulb satisfied Statement at top Gas leak. See WarningRemoving Control Valve and Burner Tube Service ProceduresRemoving Burner Orifice Location 35,000 BTU/Hr Burner Shown Changing Burner OrificeService Hints Technical Service35,000 BTU/Hr ModelParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Valve GA5010 AccessoriesIllustrated Parts List QTY Cabinet Assembly 100352 International Warranty Information