TROUBLE- SHOOTING
Continued
WARNING
If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
OBSERVED | POSSIBLE |
|
|
| |
PROBLEM | CAUSE |
| REMEDY | ||
|
|
|
|
|
|
Heater produces a | 1. | Metal expanding | while | 1. | This is common with |
clicking/ticking noise |
| heating or contracting |
| most heaters. If noise is | |
just after burner is lit |
| while cooling. |
|
| excessive, contact quali- |
or shut off. |
|
|
|
| fied service person. |
|
|
|
|
|
|
Heater produces un- | 1. | Heater burning | vapors | 1. | Ventilate room. Stop us- |
wanted odors. |
| from paint, hair | spray, |
| ing odor causing products |
|
| glues, etc. |
|
| while heater is running. |
| 2. | Low fuel supply. |
| 2. | Refill supply tank. |
| 3. | Gas leak. See Warning | 3. | Find and correct all leaks | |
|
| statement at top of |
| (see Checking Gas Con- | |
|
| page. |
|
| nections, page 13). |
|
|
|
|
|
|
Heater shuts off in use. 1. Heater not venting correctly. Vent safety switch shuts off heater.
2. Low line pressure.
3. Pilot partially clogged.
1.Check venting system. If damaged or blocked, re- pair. If venting system is OK, have qualified ser- vice person replace vent safety switch, wire har- ness, or thermocouple in- terrupter.
2.Contact local propane gas company.
3.Clean pilot (see Cleaning and Maintenance, page 25).
Gas odor even when | 1. Gas leak. See Warning | 1. | Find and correct all leaks | ||||
control knob is in OFF |
| statement at top of |
| (see Checking Gas Con- | |||
position. |
| page. |
| nections, page 13). | |||
|
| 2. | Control valve damaged. | 2. | Replace control valve. | ||
|
|
|
|
|
| ||
Gas odor during com- | 1. Foreign matter between | 1. | Take apart gas tubing and | ||||
bustion. |
| control valve and burner. |
| remove foreign matter. | |||
|
| 2. | Gas leak. See Warning | 2. | Find and correct all leaks | ||
|
|
| statement at top of |
| (see Checking Gas Con- | ||
|
|
| page. |
| nections, page 13). | ||
|
| 3. | Foreign fumes in area of | 3. | Ventilate area around | ||
|
|
| heater being drawn |
| heater to remove any for- | ||
|
|
| through burner combus- |
| eign fumes. | ||
|
|
| tion. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 29 | |
|
|
|
|
|
|
|
|
100352