Desa CGB50P, CGB35P installation manual Installing Glass Panel, Removing Lower Front Access Panel

Page 14

INSTALLING HEATER

Continued

14

INSTALLING GLASS PANEL

1. Locate the glass panel package inside the back of the heater.

WARNING ICONG 001CAUTION

Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, call DESA International’s Technical Ser- vice Department at 1-800-323-5190 for replacement glass panels.

WARNING ICONG 001CAUTION

Do not operate heater without glass panels installed. Operating heater without glass panels will damage front of heater due to excess temperatures.

WARNING ICONG 001CAUTION

Glass panels may have sharp edges. Handle with care.

2.Remove lower front access panel of heater by removing two screws at upper corners of panel. The lower front access panel covers the lower front access area (see Figure 9).

3.Remove two screws on glass guard. Remove glass guard (see Figure 9).

4.Carefully insert one glass panel up through lower front access area (see Figure 10, page 15).

5.Carefully slip glass panel behind hearth assembly (see Figure 10, page 15).

Glass

Guard

Lower Front

Access Panel

Figure 9 - Removing Lower Front Access Panel

100352

Image 14
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFor Your Safety Contents Safety Information Carbon monoxide poisoning may lead to deathSafety Information Product Identification Check GAS Type Local Codes Unpacking Product FeaturesInstallation Items Locating Heater Heater ClearancesVenting Heater Venting Heater Do not vent heater in any of the following ways see FigureVenting Heater Proper Size Vent Connecting to GAS Supply External Regulator with Vent Pointing DownGas Connection Pressure Testing Gas Supply Piping System Checking GAS ConnectionsInstalling Glass Panel Removing Lower Front Access PanelInserting Glass Panels Fresh AIR for Combustion and Ventilation Determining FRESH-AIR Flow for Heater Location Draft Hood Spillage TestVentilation Air from Outdoors Example 2 Locating Heater in Confined Closed Area Lighting Instructions For Your Safety Read Before LightingOperating Heater Viewing Pilot Shutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burner Only pilot stays litBurner Flame Pattern Inspecting Pilot and Burner FlamePilot Flame Pattern Correct Burner Flame Pattern Cleaning and Maintenance Trouble Shooting Observed Possible Problem Cause RemedyObserved Possible Remedy Problem Cause TROUBLE- ShootingStat bulb satisfied Gas leak. See Warning Statement at topService Procedures Removing Control Valve and Burner TubeRemoving Burner Changing Burner Orifice Orifice Location 35,000 BTU/Hr Burner Shown35,000 BTU/Hr Technical ServiceService Hints ModelParts Not Under Warranty Ordering Replacement Parts CentralsParts Under Warranty Accessories Valve GA5010Illustrated Parts List QTY Cabinet Assembly 100352 Warranty Information International