Bradford-White Corp THROUGH-THE-WALL GAS WATER HEATER Certain IT is Filled with Water

Page 26

Note: BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE MAIN WATER SUPPLY VALVE.

After shutting off the main water supply, open a faucet to relieve the water line pressure to prevent any water from leaking out of the pipes while making the water connections to the water heater. After the pressure has been relieved, close the faucet. The COLD water inlet and HOT water outlet are identified on the top of the water heater. The fittings at the cold water inlet and hot water outlet are dielectric waterway fittings with 3/4” NPT male thread. Make the proper plumbing connections between the water heater and the plumbing system to the house. Install a shut-off valve in the cold water supply line.

CAUTION

If sweat fittings are to be used DO NOT apply heat to the nipples on top of the water heater. Sweat the tubing to the adapter before fitting the adapter to the water connections. It is imperative that heat is not applied to the nipples containing a plastic liner.

WARNING

FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4” X 3/4”

TEMPERATURE AND PRESSURE RELIEF VALVE WILL RELEASE THE MANUFACTURER FROM ANY CLAIM THAT MIGHT RESULT FROM EXCESSIVE TEMPERATURE AND PRESSURES.

If this water heater is installed in a closed water supply system, such as one having a back-flow preventer in the cold water supply, provisions must be made to control thermal expansion. DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion. Your water supplier or local plumbing inspector should be contacted on how to control this situation

After installation of the water lines, open the main water supply valve and fill the water heater. While the water heater is filling, open several hot water faucets to allow air to escape from the water system. When a steady stream of water flows through the faucets, close them and check all water connections for possible leaks. NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING

CERTAIN IT IS FILLED WITH WATER.

26

Image 26
Contents TTW Installation and Operating Congratulations Table of Contents General Information Installation Locating The Water HeaterIf YOU Smell GAS Installation Locating The Water Heater Minimum Clearances Exceptions For Installations in Canada VentingModel Service Part Venting System CondensationVenting Part Vent Connector Lengths Length Terminal Through the Wall Venting Through the Roof Venting Vertical VentingThrough the Wall Venting with LOW Ground Clearance Venting Part LOW Ground Clearance Installations Vent Connector Lengths for 3 7.6 cm Diameter PVC Terminating # of 90 Elbows Maximum Minimum Through the Wall Venting Through the Roof Venting Vertical Venting Through the Wall Venting with LOW Ground Clearance High Altitude Vent Connector Modifications Cm Vent Connector Lengths from Inside Wall for LOWGround Clearance Installations Unconfined Spaces Combustion Air SupplyDo not Operate Appliance Until Leakage is Corrected Confined SpacesSpecially Engineered Installations Water ConnectionsCertain IT is Filled with Water Page Installation Water Connections Match or Open Flame for Testing Gas ConnectionsElectrical Connections Electrical Connections Figure Electrical Connections Figure General Operation Lighting and shutdown instructions Thermostat Adjustment Burner Flame CheckMaintenance Maintenance Page Time That Parts and the Water Heater are Warranted Parts List Drawing Part Name and Description Page Vent Pipe Preparation and Joining