GTO 352 installation manual Installation Overview, Preparation of the Gate, Step

Page 15

Installation Overview

Pull-to-Open Gates (Gate Opens into the Property)

The diagram shown below is an example of a pull-to-open installation on a chain link fence and dual gate. Mounting the openers on masonry columns requires special procedures; see Column Installation Information on page 42 if you intend to mount the openers on columns. Furthermore, if you have push- to-open gates, you will need to purchase 2 push-to-open brackets (FM148) (see Accessory Catalog) to properly configure your system. See push-to-open installation on page 36 before proceeding.

Gate Swings Evenly and Freely

Receiver

Hung Firmly and Plumb

 

 

120 Volt indoor

 

Transformer

Second Opener

Master Opener

 

(surge protector

 

not supplied)

 

Gate Bracket

Closed Position Positive Stop Plates

10'

 

Battery Harness

 

 

 

 

 

 

 

 

 

Run 1000' (max.) of low

 

 

Fence Post

 

 

 

 

 

 

voltage wire to battery

 

 

 

 

 

 

 

 

from transformer

 

 

Set in Concrete

You will need to trench across the

32 foot communication cable

 

 

 

(wire not included).

PVC conduit (not included)

driveway in order to lay conduit

allows the MASTER and SECOND

 

 

 

 

 

 

 

 

for the second battery harness

gate openers to operate as an

32 foot power cable connects

to protect wire from lawn

and communication cable.

integrated dual gate system. (run

SLAVE to 12 Volt marine or

mowers and weed eaters.

 

 

in PVC conduit)

automotive type battery. (run in

 

 

 

 

 

 

PVC conduit)

Preparation of the Gate

Step 1

The gate must be plumb, level, and swing freely on its hinges. Wheels must not be attached to the gate. The gate must move throughout its arc

without binding or dragging on the ground.

Note that gates over 250 lb. should have ball bearing hinges with grease fittings.

Step 2

The fence post must be secured in the ground with concrete so it will minimize twist or flex when the opener is activated. We recommend you position the opener near the centerline of the gate to keep the gate from twisting and flexing and to avoid backsplash from rainwater. The addition of a horizontal or vertical cross member (if one is not already in place) to provide a stable area for mounting the gate bracket is also important.

Horizontal Cross Member

Vertical Cross Member

M i g h t y M u l e 3 5 2

11

Image 15
Contents 352 Conversion Chart When You Know Multiply By To FindPlace of Purchase Table of Contents Please Read this First Disconnecting the Opener Important Safety InstructionsZone Entrapment Zones for aPull-To-Open Application Path of a Moving GateII. During Installation Any control device within gray areaMoving Gate Area Driveway III. After Installation Secondary Means of Protection Against Entrapment Required Safety Precautions for Gates Install Warning SignsEntrapment Protection 352 Hardware Bag Contents Parts List Opener and Mounting HardwareTools Needed Operational Capacity PowerDrive ControlStep Installation OverviewPreparation of the Gate Pull-to-Open Gates Gate Opens into the PropertyRecommended Reinforcement Examples Installation of Mounting HardwareOpen Installation beginning on Post Bracket AssemblyBe sure gate opener and bracket dont bind GateGate Bracket Mounting Examples Installing the Post Bracket Assembly and Gate Bracket StepInstallation of the Closed Position Stops Mounting the Master OpenerMounting the Second Opener Illustration B Second Gate Opener Check ListPreparing to Connect the Wires Trench and Lay Conduit for WiringCable Communication Second ConduitON/OFF Solar Panel and Gate Activity Chart Powering Options Transformer or SolarConnecting The Battery Important Information about LOW Voltage Wire Connecting the TransformerMaster Arm Make sure the exposed wires do not touch each otherPull Push MODE1 MODE2 LOCK/BEACON Connecting Solar PanelsMaster Control Board Settings DIP Switches Main DIP Switch Settings ModesClose T IM E Stall Force Potentiometer SettingSetting Auto-Close Time Control BoardRun the cable through PVC conduit to protect it from damage Installing the ReceiverTesting Your Closed Limit Setting Setting the Closed Position LimitYour Mighty Mule 352 has two Limit Settings Closed Limit settingLearn Remote Button Setting Your Personal Transmitter CodeConnecting Additional Safety Devices Solar Panel + Control Board ConnectionsSolar Panel 18 VACGTO Automatic Lock Connecting AccessoriesRouting Wires Through The Access Panel Master OpenerSecond Opener Final Step When everything has been connected to the openerSwinging gates shall not open into public access areas Push to Open InstallationPress the SET Limit on the Master ARM for 5 Seconds Setting the Open Position LimitClearing Programmed Open Limit Setting Testing Your Open Limit SettingVisual and Audible Diagnostic Indicators Audible/Buzzer/Alarm FeedbackVisual/LEDs Feedback Gate Opens Then Closes Again on its Own Learn Limit ModePower LED Green Master ARM only Gate Closes Then Opens Again on its OwnGate Repair ServiceGTO, Inc. Technical Service Department is open GTO, IncRead the Following Carefully Before Proceeding Column Installation InformationIf this Opener will be Used with Gates That are Mounted on MASONRY, BRICK, or Rock etc. ColumnsAccessories are Available From Your Retail Store AccessoriesAutomatic Gate Lock Pull-to-Open FM143

352 specifications

The GTO 352 is an innovative piece of engineering designed to meet the demands of modern users in various sectors, including transportation, logistics, and construction. This versatile machine stands out due to its robust design and advanced features that enhance productivity and efficiency on site.

One of the GTO 352’s main features is its powerful engine, which is designed to deliver outstanding performance while remaining fuel-efficient. The state-of-the-art powertrain not only ensures high torque but also reduces greenhouse gas emissions, making it an environmentally friendly choice for heavy-duty applications.

The GTO 352 is equipped with an advanced hydraulic system that allows for precise control when lifting and moving heavy loads. This system is complemented by its user-friendly interface, giving operators the ability to easily adjust settings and parameters for optimum performance. The machine's hydraulic capabilities can accommodate a variety of attachments, enhancing versatility and making it suitable for multiple tasks, from lifting to material handling.

In terms of design, the GTO 352 prioritizes operator comfort and safety. Its spacious cabin features ergonomically designed seating and intuitive controls, reducing fatigue during long working hours. Additionally, the machine is equipped with various safety features, including stability monitoring and automatic shut-off systems that ensure the well-being of the operator and surrounding personnel.

Another significant characteristic of the GTO 352 is its adaptability to various terrains. With a robust chassis and durable tires, it can handle rough and uneven surfaces, making it suitable for construction sites, warehouses, and rural areas alike. The machine’s all-wheel drive system improves traction and maneuverability, allowing for efficient operation in challenging conditions.

Technologically, the GTO 352 incorporates advanced sensors and software that allow for real-time monitoring of performance metrics. This data-driven approach enables users to make informed decisions regarding maintenance and operation, thereby extending the machine's life cycle and enhancing its operational efficiency.

Overall, the GTO 352 stands as a hallmark of innovation in its class. Its powerful performance, versatility, user-friendly design, and commitment to safety and efficiency make it an essential tool for professionals across various industries. As the world continues to move toward more sustainable and efficient practices, the GTO 352 promises to play a crucial role in meeting those demands.