1. 1 beep with 2 seconds off:

Limit switch error: Limit switch’s normally open and normally close inputs both open or both shorted. Circuit board is indicating faulty limit switch inside the operator. The alarm will automatically shut off in 4 seconds after the problem is corrected. Call Tech Support.

2. 5 beeps with 2 seconds off:

Low battery condition detected:

-Check battery voltage to ensure you have 12.5 to 13.5 Vdc

-Check transformer output to ensure you have 18-22 Vac

-Check charging circuit with transformer or solar panel connected to ensure battery is being charged to

13.8to 14.8 vDC. Battery may be charged with a trickle charger at 12Vdc 2 amps for 3 to 4 hours but be sure to disconnect it from the system.

3.1 beep when attempt to run the unit:

-Blown fuse

-Dead cell or extremely low battery condition.

-Bad connection from battery to circuit board.

4.Alarm continuously beeps (remote does not operate unit AND not at either limits):

-Two consecutive obstructions have been detected without reaching the limit. Alarm

will automatically shut off after 5 minutes. ‘Power-cycle’ the unit will also shut off the alarm.

-The battery may be extremely low.

5.Learn Remote: (MASTER ARM ONLY)

When a new code is learned from the remote the alarm will sound. Release the ‘LEARN REMOTE’ button will turn the alarm off. See "Setting Your Personal Transmitter Code" section on page 30.

6. Power-Cycle:

The alarm will beep for 1 second upon power up to indicate the opener is ready to operate.

Visual/LEDs Feedback:

1.RF LED (LED2): (MASTER ARM ONLY)

Blinking when there is 318 MHz signal is received. This LED is typically off when the receiver is connected and no 318 MHz signal is presented.

If no light:

a.Check receiver connection on the control board

b.Replace the battery in the remote.

c.Relocate antenna

d.Re-learn the remote

M i g h t y M u l e 3 5 2

39

Image 43
Contents 352 When You Know Multiply By To Find Conversion ChartPlace of Purchase Table of Contents Please Read this First Disconnecting the Opener Important Safety InstructionsZone Entrapment Zones for aPull-To-Open Application Path of a Moving GateAny control device within gray area II. During InstallationMoving Gate Area Driveway III. After Installation Secondary Means of Protection Against Entrapment Install Warning Signs Required Safety Precautions for GatesEntrapment Protection 352 Hardware Bag Contents Parts List Opener and Mounting HardwareTools Needed Operational Capacity PowerDrive ControlStep Installation OverviewPreparation of the Gate Pull-to-Open Gates Gate Opens into the PropertyRecommended Reinforcement Examples Installation of Mounting HardwareOpen Installation beginning on Post Bracket AssemblyBe sure gate opener and bracket dont bind GateGate Bracket Mounting Examples Installing the Post Bracket Assembly and Gate Bracket StepMounting the Master Opener Installation of the Closed Position StopsMounting the Second Opener Illustration B Second Gate Opener Check ListPreparing to Connect the Wires Trench and Lay Conduit for WiringCable Communication Second ConduitON/OFF Solar Panel and Gate Activity Chart Powering Options Transformer or SolarConnecting The Battery Important Information about LOW Voltage Wire Connecting the TransformerMaster Arm Make sure the exposed wires do not touch each otherPull Push MODE1 MODE2 LOCK/BEACON Connecting Solar PanelsMaster Control Board Settings DIP Switches Main DIP Switch Settings ModesClose T IM E Stall Force Potentiometer SettingSetting Auto-Close Time Control BoardRun the cable through PVC conduit to protect it from damage Installing the ReceiverTesting Your Closed Limit Setting Setting the Closed Position LimitYour Mighty Mule 352 has two Limit Settings Closed Limit settingLearn Remote Button Setting Your Personal Transmitter CodeConnecting Additional Safety Devices Solar Panel + Control Board ConnectionsSolar Panel 18 VACGTO Automatic Lock Connecting AccessoriesMaster Opener Routing Wires Through The Access PanelSecond Opener Final Step When everything has been connected to the openerSwinging gates shall not open into public access areas Push to Open InstallationPress the SET Limit on the Master ARM for 5 Seconds Setting the Open Position LimitClearing Programmed Open Limit Setting Testing Your Open Limit SettingAudible/Buzzer/Alarm Feedback Visual and Audible Diagnostic IndicatorsVisual/LEDs Feedback Gate Opens Then Closes Again on its Own Learn Limit ModePower LED Green Master ARM only Gate Closes Then Opens Again on its OwnGate Repair ServiceGTO, Inc. Technical Service Department is open GTO, IncRead the Following Carefully Before Proceeding Column Installation InformationIf this Opener will be Used with Gates That are Mounted on MASONRY, BRICK, or Rock etc. ColumnsAccessories are Available From Your Retail Store AccessoriesAutomatic Gate Lock Pull-to-Open FM143

352 specifications

The GTO 352 is an innovative piece of engineering designed to meet the demands of modern users in various sectors, including transportation, logistics, and construction. This versatile machine stands out due to its robust design and advanced features that enhance productivity and efficiency on site.

One of the GTO 352’s main features is its powerful engine, which is designed to deliver outstanding performance while remaining fuel-efficient. The state-of-the-art powertrain not only ensures high torque but also reduces greenhouse gas emissions, making it an environmentally friendly choice for heavy-duty applications.

The GTO 352 is equipped with an advanced hydraulic system that allows for precise control when lifting and moving heavy loads. This system is complemented by its user-friendly interface, giving operators the ability to easily adjust settings and parameters for optimum performance. The machine's hydraulic capabilities can accommodate a variety of attachments, enhancing versatility and making it suitable for multiple tasks, from lifting to material handling.

In terms of design, the GTO 352 prioritizes operator comfort and safety. Its spacious cabin features ergonomically designed seating and intuitive controls, reducing fatigue during long working hours. Additionally, the machine is equipped with various safety features, including stability monitoring and automatic shut-off systems that ensure the well-being of the operator and surrounding personnel.

Another significant characteristic of the GTO 352 is its adaptability to various terrains. With a robust chassis and durable tires, it can handle rough and uneven surfaces, making it suitable for construction sites, warehouses, and rural areas alike. The machine’s all-wheel drive system improves traction and maneuverability, allowing for efficient operation in challenging conditions.

Technologically, the GTO 352 incorporates advanced sensors and software that allow for real-time monitoring of performance metrics. This data-driven approach enables users to make informed decisions regarding maintenance and operation, thereby extending the machine's life cycle and enhancing its operational efficiency.

Overall, the GTO 352 stands as a hallmark of innovation in its class. Its powerful performance, versatility, user-friendly design, and commitment to safety and efficiency make it an essential tool for professionals across various industries. As the world continues to move toward more sustainable and efficient practices, the GTO 352 promises to play a crucial role in meeting those demands.