Allstar Products Group J6500, 6000, 6500-P owner manual Fastening Limit CAM to Chain

Page 12

C: INSTALLING THE OPERATOR

STEP 9: Consult the label on the rear panel of the Opener to determine its proper working voltage. Normally it will be marked for 115V, 60 cycle operation. (If it is an export model designed for 220V, 50 cycle operation, the label will clearly indicate this.) The Opener must be plugged into a properly grounded receptacle within 3 FT of the Power Unit. A GFI Type receptacle is recommended. Do not use 2-prong adapters and do not use extension cords for anything more than temporary hook-up and testing purposes. Receptacle wiring should be No. 14 or heavier, and must be in compliance with local building and electrical codes.

WARNING

DISCONNECT POWER AT FUSE BOX AND OPENER BEFORE WIRING PERMANENTLY TO PREVENT ELECTROCUTION.

WARNING

IMPROPER WIRING COULD CAUSE ELECTROCUTION OR DAMAGE TO CIRCUITRY. FOLLOW LOCAL BUILDING AND

If local codes require permanent wiring, a GFI type circuit breaker is recommended to protect the line. Remove the Strain Relief Bushing and

withdraw the Line Cord from the rear of the Power Unit to expose the three104380 insulated connectors. Cut the wire at the rubber jacket of the Line Cord and

wire in permanently, employing proper wiring practices. Discard Strain Relief. It is not used with permanent wiring.

Step 10: Install a Rough Service lamp bulb (75 Watt maximum) firmly in the light socket. Light bulbs in Door Openers are subject to vibration during normal operation which may shorten their life spans. Rough Service bulbs, available at most hardware stores, are recommended. Fit Light Diffuser tabs into the panel slots as shown.

104381

106428

STEP 11: On most models, the Limit Cams are installed at the factory. If the Limit Cams have not been installed, fasten them to the Chain in the approximate positions illustrated above. Position the Switch Actuators as shown above.

FASTENING LIMIT CAM TO CHAIN

12

Image 12
Contents Series Table of Contents Product Features Standard FeaturesComponent Identification Tools RequiredAssembly Instructions StepAdjustment Installing the Operator For These Types of Doors USE 1/3 HPUSE 7 FT, 8 FT or 10 FT Rail Match Door Height For These Types of Doors USEMounting the Front Bracket One High ARC Rise High ARC Rise Horizontal LineSectional Doors and ONE ONE Piece Doors Piece Doors with Tracks Without TracksInstalling Door ARM Connection and InstallationDouble OverhandKnot ReleaseFastening Limit CAM to Chain Final Installation Auxiliary EquipmentIllustration, left. Check to ensure the Window on the Front Photosystem Unit is Within the Limit Marks on the Door JambFinal Alignment and Test TransmitterInstallation of the Super Station Operating Parameters Check with Your Local Building Inspector FirstIf the Door is Downward108407 Operation and Adjustment R NI N GOperation and Adjustment Instructions Testing the All-Clear PhotosystemOperator Wiring Diagram Wiring Auxiliary Equipment Installation Checklist Troubleshooting Guide Symptom Probable CAUSE/SOLUTIONSolution Probable CauseAllstar Corporation Downingtown, PA