C:INSTALLING THE OPERATOR

STEP 2: Raise the Tee Rail so that the Front Idler Bracket and

 

Front Mounting Bracket align. Insert bolt and tighten nut loosely for

 

now. Later in the installation, this nut must be tightened securely.

 

STEP 3 — Sectional Doors and One Piece Doors with Track:

 

Raise the Opener and rest the Power Unit on a ladder or other sturdy

 

support. Open the door the full open position. Allow 2" of space

 

between the Tee Rail and the top section of the door (as shown in the

 

illustration, below, far left).

 

 

STEP 3A — One Piece Doors without Track: Raise the opener

 

and rest the power unit on a ladder or other sturdy support. Open the

 

door to the high arc position. Allow 2” of space between the tee rail

 

and the door (at the high arc position) as shown in the illustration,

 

below, left. The opener will be angled as shown. This is necessary

 

for proper operation.

 

 

NOTE: Since the Opener will be secured permanently in this

104372

position, open and close the door a few

 

 

 

times to be sure the door does not rub on the

 

 

Tee Rail and that you have allowed the

SECTIONAL DOORS AND ONE-

ONE PIECE DOORS

proper clearances before proceeding.

 

PIECE DOORS WITH TRACKS

WITHOUT TRACKS

STEP 4: Mount Power Head to Ceiling:

Since there is such variety in ceiling

ALLOW 2” BETWEEN

ALLOW 2” BETWEEN

TOP OF DOOR AND RAIL

structures, all the mounting possibilities for

HIGH ARC

 

the Power Unit cannot be illustrated here.

 

 

The main concern is mounting the Power

 

TOP OF

Unit securely to the ceiling joists for

DOOR FULLY

DOOR IN

operational

strength, rigidity and safety.

HIGH ARC

Although there are a series of mounting slots

OPEN

POSITION

 

 

provided on the power unit, try to secure

 

 

the mounting straps in the slots closest to

 

 

the front.

Mounting may usually be

 

104373

accomplished using standard

 

 

 

1-1/4“ perforated steel angle available at most hardware stores. If in doubt about location of, and attachment to, ceiling joists, a carpenter should be contacted to provide assistance. A cross brace will be necessary if power head is mounted 8” or more from the ceiling.

STEP 5: Return to the Tee Rail/Front Mounting Bracket and securely tighten the bolt and nut that connect the Tee Rail Front Idler bracket and the Front Mounting Bracket. (See Step 2, above).

104375

Secure Head Unit to ceiling framing using angle iron (not provided).

104374

NOTE: The Model 6500-P is provided with vibration isolator mounts. Position as shown above.

9

Image 9
Contents Series Table of Contents Standard Features Product FeaturesTools Required Component IdentificationStep Assembly InstructionsAdjustment For These Types of Doors USE 1/3 HP Installing the OperatorUSE 7 FT, 8 FT or 10 FT Rail Match Door Height For These Types of Doors USEHigh ARC Rise High ARC Rise Horizontal Line Mounting the Front Bracket OnePiece Doors with Tracks Without Tracks Sectional Doors and ONE ONE Piece DoorsDoor ARM Connection and Installation InstallingOverhand DoubleKnot ReleaseFastening Limit CAM to Chain Auxiliary Equipment Final InstallationIllustration, left. Check to ensure the Window on the Front Photosystem Unit is Within the Limit Marks on the Door JambTransmitter Final Alignment and TestInstallation of the Super Station Check with Your Local Building Inspector First Operating ParametersIf the Door is Downward108407 R NI N G Operation and AdjustmentTesting the All-Clear Photosystem Operation and Adjustment InstructionsOperator Wiring Diagram Wiring Auxiliary Equipment Installation Checklist Symptom Probable CAUSE/SOLUTION Troubleshooting GuideSolution Probable CauseAllstar Corporation Downingtown, PA