F:OPERATION AND ADJUSTMENT INSTRUCTIONS

A DAMAGED OR MALFUNCTIONING PHOTOELECTRIC ACCESSORY SYSTEM COULD ENABLE A GARAGE DOOR TO CLOSE ON PEOPLE OR PROPERTY, CAUSING SERIOUS INJURY OR DEATH. PERFORM THIS TEST MONTHLY TO ENSURE YOUR ALL-CLEARIS WORKING PROPERLY.

STEP 5: Testing the All-Clear™ Photosystem —

Start the door in the close travel direction and then place an obstacle approximately 8" high by 12" wide in the path of the beam. The Red Pilot Light on the All-Clear™ Photosystem should go out. The door should stop and reverse to the full open position.

With the door fully open and at rest, place the obstacle in the path of the beam once again. Activate the Standard Wall Push Button. The opener should revert to and remain in the PUSH AND HOLD mode of operation for close travel.

IF THE GARAGE DOOR TRAVELS MORE THAN ONE INCH IN A DOWNWARD PATH AFTER RELEASING THE BUTTON, THE ALL-

CLEAR™ SYSTEM IS MALFUNCTIONING. CHECK THE ELECTRICAL CONNECTIONS AND ALIGNMENT OF THE ALL- CLEAR™.

104393

STEP 6: Operating the Super Station (Deluxe Wall Pushbutton Station) Controls — The Super Station replaces standard doorbell-type pushbuttons to allow you to integrate fully with all the convenience and security features built into your 6000 Series garage door operator.

1.Operator Open Pushbutton — Green-backlighting, arrow pointing up. Used to start the door upward. This button will also stop and reverse a door that is closing. The button has no effect on a door that is opening. The function of this pushbutton is automatically disabled when the Security slide switch is set to the “ON” position and the door is fully closed.

2.Operator Close Pushbutton — Green-backlighting, arrow pointing down. Used to start the door downward. This button has no effect on a door in motion.

3.Operator Stop Button - Red-backlighting, universal “STOP” within an octogon. Used to stop a door in motion. This button has no effect on a door that is stopped.

4.Operator Light Pushbutton Yellow-backlighting, “Sun” symbol. Turns

104394

 

the

operator light on and off, but does not activate the door operator. The

 

 

operator light will stay on until turned off using this pushbutton, or until door

Operator

 

operation is initiated, which overrides the function of this pushbutton and

OPEN

Operator

automatically turns the light off after 4-1/2 minutes.

Button

 

 

STOP

5.

Security Switch — Prevents unwanted door operation from pushbutton, key

 

Operator

Button

switches, keyless entry systems, radio controls, etc. When the Security Switch is

 

 

moved to the ON position (towards “locked” symbol), with the garage door fully

CLOSE

 

Button

Operator

closed, signals from all of these devices are locked out by the operator. Such

 

Light

devices will continue to work until the door is fully closed, allowing you to set

 

Button

the switch (when leaving on vacation, for example), leave the garage and close

Security

 

the door remotely.

 

(NOTE: YOU WILL NOT BE ABLE TO OPEN YOUR GARAGE DOOR

Disable

Security

USING RADIO CONTROLS OR EXTERIOR ACCESS CONTROLS UNTIL

Switch

Switch

 

THE SECURITY SWITCH IS RETURNED TO THE OFF POSITION

 

 

 

 

(“unlocked” symbol). THIS MUST BE DONE FROM INSIDE THE

GARAGE.)

When the Security Switch is engaged, the green lighting behind the Open/Close Pushbuttons is extinguished as an

indication.

 

 

 

6.Security Disable Switch - located under and to the left of the Security Switch. Disables the Security Switch feature. Use if the garage door is the only entryway to the garage.

19

Image 19
Contents Series Table of Contents Standard Features Product FeaturesTools Required Component IdentificationStep Assembly InstructionsAdjustment For These Types of Doors USE Installing the OperatorFor These Types of Doors USE 1/3 HP USE 7 FT, 8 FT or 10 FT Rail Match Door HeightHigh ARC Rise High ARC Rise Horizontal Line Mounting the Front Bracket OnePiece Doors with Tracks Without Tracks Sectional Doors and ONE ONE Piece DoorsDoor ARM Connection and Installation InstallingRelease DoubleOverhand KnotFastening Limit CAM to Chain Photosystem Unit is Within the Limit Marks on the Door Jamb Final InstallationAuxiliary Equipment Illustration, left. Check to ensure the Window on the FrontTransmitter Final Alignment and TestInstallation of the Super Station Downward Operating ParametersCheck with Your Local Building Inspector First If the Door is108407 R NI N G Operation and AdjustmentTesting the All-Clear Photosystem Operation and Adjustment InstructionsOperator Wiring Diagram Wiring Auxiliary Equipment Installation Checklist Probable Cause Troubleshooting GuideSymptom Probable CAUSE/SOLUTION SolutionAllstar Corporation Downingtown, PA