Allstar Products Group J6500, 6000, 6500-P owner manual Mounting the Front Bracket One

Page 8

C: INSTALLING THE OPERATOR

104370

Door

Header Bracket

Bracket Distance Above Floor (See Chart)

Highest Point

of Travel

Measure Distance to Floor

Garage

Floor

STEP 1A: Mounting the Front Bracket — One

Piece Doors Without Track: Mark a vertical centerline on the header above the door. Manually raise the door to its high arc position and temporarily clamp in that position. With the door in this high arc position, measure the distance from the top of the door to the floor (see figure at left). Subtract the actual door height from the high arc distance to the floor. This is the high arc rise of the door. Unclamp and close the door. Using the table below, draw a horizontal line at the appropriate height above the door to intersect with the vertical centerline.

104371

HIGH ARC RISE

HIGH ARC RISE HORIZONTAL LINE

 

 

4 INCHES

6 INCHES

 

 

4 TO 8 INCHES

11 INCHES

 

 

8 TO 12 INCHES

16 INCHES

 

 

Mount the Front Mounting Bracket securely with lag screws as shown in figure below. If necessary, reinforce the header with steel angle iron or wood to ensure a secure mount.

VERTICAL

CENTERLINE

HIGH ARC (RISE)

HORIZONTAL LINE

LAG SCREWS 5/16” X 1-7/8”

8

Image 8
Contents Series Table of Contents Product Features Standard FeaturesComponent Identification Tools RequiredAssembly Instructions StepAdjustment Installing the Operator For These Types of Doors USE 1/3 HPUSE 7 FT, 8 FT or 10 FT Rail Match Door Height For These Types of Doors USEMounting the Front Bracket One High ARC Rise High ARC Rise Horizontal LineSectional Doors and ONE ONE Piece Doors Piece Doors with Tracks Without TracksInstalling Door ARM Connection and InstallationDouble OverhandKnot ReleaseFastening Limit CAM to Chain Final Installation Auxiliary EquipmentIllustration, left. Check to ensure the Window on the Front Photosystem Unit is Within the Limit Marks on the Door JambFinal Alignment and Test TransmitterInstallation of the Super Station Operating Parameters Check with Your Local Building Inspector FirstIf the Door is Downward108407 Operation and Adjustment R NI N GOperation and Adjustment Instructions Testing the All-Clear PhotosystemOperator Wiring Diagram Wiring Auxiliary Equipment Installation Checklist Troubleshooting Guide Symptom Probable CAUSE/SOLUTIONSolution Probable CauseAllstar Corporation Downingtown, PA