Motor Control Board
Motor Control Board
Removal
120V Models:
1.Perform Pressure Relief Procedure, see page 4. Wait 5 minutes before servicing.
2.Remove Power Module, see page 7.
3.Disconnect material hose (79) from pump (18a).
79
18a
ti15616a
4.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
ti15624a
5.Remove four screws (33b) and display cover (33k). 33k
33b | ti15786a |
6.Disconnect display connector (A) from motor control board (24) and remove display.
ti13569a
24
A
7.Remove bottom two screws (61) and remove control panel (37).
37
61
ti15795a
8.Disconnect Prime/Tool Fill/Recirculate reed switch connector (E) from motor control board (24).
24
E
ti13572a
9.Disconnect potentiometer connector (C) from motor control board (24).
24
ti15791a
C
10.Disconnect 15/20A switch connector (X) from motor control board (24).
24
X
ti15850a
12 | 3A0246C |