Digital Display

Digital Display

Removal

1.Turn off unit. Wait 5 minutes before servicing.

2.Remove four screws (33b) and remove display cover (33k).

33k

ti15786a

33b

3.Unplug display board connector from motor control board (24).

24

ti13569a

A

Installation

1.Plug display board connector (A) into motor control board (24).

ti13569a24

A

2.Replace display cover (33k) and torque four screws (33b) to 30-35 in-lb.

33k

ti15786a

33b

NOTE: Make sure noise shield tabs are routed to the inside of the control box when assembling.

26

3A0246C

Image 26 Contents
Drywall Feed Pump Electric Shock Hazard Moving Parts Hazard Pressure Relief Procedure Drive and Bearing Housing Installation Power Module Perform Pressure Relief Procedure, see PumpPush pump up until pump threads engage Motor Reconnect three wire harnesses see Wiring Diagrams, pages Motor Control Board 120V ModelsRemove two top screws 61 and control box UK and 240V Models Remove top two screws 61 and control box Apply new thermal paste into both pockets of heat sink Connect white power cord conductor D to motor control board UK and 240V Models Reconnect material hose 79 to pump 18a Prime Valve Handle Pressure Transducer 33b Flow Control Adjust Potentiometer Connect display connector a to motor control board Prime/Tool Fill/Recirculation Reed Switch Removal InstallationDigital Display Inline Valve Changing the NeedleReplacing the Battery Box Slide ControlParts Description QtyPump Module Parts Pump Module Parts List Part Description QtyInline Valve Parts 24F538 CableBox Slide Parts 24F463 Wiring Diagrams VAC NA UnitsVAC UK VAC Units Technical Data Unit Technical Data Pump3A0246C 3A0246C Graco Standard Warranty Graco Information
Related manuals
Manual 32 pages 32.7 Kb