Graco 257100, 262300, 262288, 258907, 258906 manual Push pump up until pump threads engage

Page 9

3. Push pump up until pump threads engage.

Pump

7.Replace pump rod shield (48) and torque two screws (40) to 30 - 34 in-lb.

40

48

ti15924a

4.Screw in pump until threads are flush with drive housing opening.

ti15621a

5.Align pump outlet to right side so that hose can be reassembled.

ti15923a

6.Screw jam nut up toward drive housing until nut stops. Tighten jam nut by hand, then tap 1/8 to 1/4 turn with a 20 oz. (maximum) hammer to approximately 75± 5 ft-lb (102 N•m).

ti15925a

ti15619a

8. Reconnect material hose (79) to pump (18a).

79

18a

ti15616a

9. Replace Power Module, see page 7.

3A0246C

9

Image 9 Contents
Drywall Feed Pump Electric Shock Hazard Moving Parts Hazard Pressure Relief Procedure Drive and Bearing Housing Installation Power Module Pump Perform Pressure Relief Procedure, seePush pump up until pump threads engage Motor Reconnect three wire harnesses see Wiring Diagrams, pages 120V Models Motor Control BoardRemove two top screws 61 and control box UK and 240V Models Remove top two screws 61 and control box Apply new thermal paste into both pockets of heat sink Connect white power cord conductor D to motor control board UK and 240V Models Reconnect material hose 79 to pump 18a Prime Valve Handle Pressure Transducer 33b Flow Control Adjust Potentiometer Connect display connector a to motor control board Removal Installation Prime/Tool Fill/Recirculation Reed SwitchDigital Display Changing the Needle Inline ValveBox Slide Control Replacing the BatteryDescription Qty PartsPump Module Parts Part Description Qty Pump Module Parts ListCable Inline Valve Parts 24F538Box Slide Parts 24F463 VAC NA Units Wiring DiagramsVAC UK VAC Units Technical Data Pump Technical Data Unit3A0246C 3A0246C Graco Information Graco Standard Warranty
Related manuals
Manual 32 pages 32.7 Kb