Drive and Bearing Housing
NOTICE
Do not drop gear cluster (17a) when removing drive housing (5a). Gear cluster may stay engaged in motor front end bell or drive housing.
Removal
1.Perform Pressure Relief Procedure, page 4.
2.Remove Power Module, see page 7.
3.Remove Pump, page 8.
4.Remove four screws (40) and lift motor shroud (98) off of motor.
40
98
ti15624a
5.Disconnect three wire harnesses (see Wiring Diagrams, pages
Drive and Bearing Housing
6.Remove two screws (5b) from underneath motor base plate. Lift and remove motor/pump assembly from power module.
5b
ti11734a
7.Loosen four screws (19) on pump housing, and remove bearing housing (9) from motor.
9
ti15630a
19
8.Remove three screws (5c) on motor (8a). Remove motor (8a) from drive housing (5a).
8a
5a
5c
ti11735a
3A0246C | 5 |