12. Remove top two screws (61) and control box (3).

61

3

ti15912a

13.Disconnect transducer connector from motor control board (24).

ti12999a

24

14.Disconnect three motor connectors from motor con- trol board to motor.

ti15847a

Motor Control Board

15.Remove two screws (83) holding motor control board / heat sink assembly to power module frame. Remove motor control board/heat sink assembly.

83

ti15845a

16.Remove six outer screws, two inner screws, and remove control board (24) from heat sink.

24

ti15844a

3A0246C

15

Image 15 Contents
Drywall Feed Pump Electric Shock Hazard Moving Parts Hazard Pressure Relief Procedure Drive and Bearing Housing Installation Power Module Pump Perform Pressure Relief Procedure, seePush pump up until pump threads engage Motor Reconnect three wire harnesses see Wiring Diagrams, pages 120V Models Motor Control BoardRemove two top screws 61 and control box UK and 240V Models Remove top two screws 61 and control box Apply new thermal paste into both pockets of heat sink Connect white power cord conductor D to motor control board UK and 240V Models Reconnect material hose 79 to pump 18a Prime Valve Handle Pressure Transducer 33b Flow Control Adjust Potentiometer Connect display connector a to motor control board Removal Installation Prime/Tool Fill/Recirculation Reed SwitchDigital Display Changing the Needle Inline ValveBox Slide Control Replacing the BatteryDescription Qty PartsPump Module Parts Part Description Qty Pump Module Parts ListCable Inline Valve Parts 24F538Box Slide Parts 24F463 VAC NA Units Wiring DiagramsVAC UK VAC Units Technical Data Pump Technical Data Unit3A0246C 3A0246C Graco Information Graco Standard Warranty
Related manuals
Manual 32 pages 32.7 Kb