Hitachi 236464 manual Operation/Maintenance, Pressure Relief Procedure, Packing Nut/Wet-Cup, 110

Page 10

Operation/Maintenance

Pressure Relief Procedure

WARNING

INJECTION HAZARD

The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid

under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Dare instructed to relieve the pressure,

Dstop spraying,

Dcheck or service any of the system equipment,

Dor install or clean the spray tips.

1.Lock the gun trigger safety.

2.Shut off the air supply to the pump.

3.Close the bleed-type master air valve (required in your system).

4.Unlock the gun trigger safety.

5.Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.

6.Lock the gun trigger safety.

7.Open the drain valve (required in your system), having a container ready to catch the drainage.

8.Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.

Packing Nut/Wet-Cup

Before starting, fill the packing nut (8) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent. See Fig. 3.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

The packing nut is torqued at the factory and is ready for operation. If it becomes loose and there is leaking from the throat packings, relieve pressure, then torque the nut to 61–75 NSm (45–55 ft-lb) using the supplied wrench (110). Do this whenever necessary. Do not overtighten the packing nut.

Torque to 61–75 NSm

1(45–55 ft-lb)

Model 237634 Shown

18

110

04373

Fig. 3

10 308350

Image 10 Contents
Instructions Parts List Dura-Flot600 PumpsTable of Contents List of ModelsSymbols Equipment Misuse HazardInjection Hazard Moving Parts HazardFire and Explosion Hazard Toxic Fluid Hazard 308350 General Information Grounding InstallationSystem Accessories Object being sprayed follow your local codeAir Line Accessories Typical Installation KEYPacking Nut/Wet-Cup Operation/MaintenancePressure Relief Procedure 110Starting and Adjusting the Pump Flush the Pump Before First UseShutdown and Care of the Pump FlushingIts stroke keep the wet-cup 1/3 filled with a Troubleshooting ChartCompatible solvent Reconnecting the Displacement Pump ServiceDisconnecting the Displacement Pump Required Tools101 105 108 107 106 110 109Displacement Pump Service DisassemblyTorque to 258-285 NSm 190-210 ft-lb Reassembly 10 Ref 11 Ref Sealing surface of the intake housing Install the seal 11* on the bottomHousing 7 onto the cylinder handtight. Using a pipe wrench, torque the intake housing101 105 108 109 102Y 107 106 110 Parts102Y 107 106 110 102Y 107 110 106 112 Part No Pump, Series a 251 Ratio, with Senator Air Motor101 105 108 109 113Throat Packing Stack see Piston Packing Stack SeeUHMWPE/Leather Packing Kit 237238 Optional Packing KitsTeflonr Packing Kit 237236 Optional UHMWPE/PTFErPacking Kit 237609 OptionalTechnical Data Tested in accordance with ISOLiters/min 11.4 Dimensions Mounting Hole LayoutGraco Standard Warranty Graco Information