Hitachi 236464 manual Reassembly

Page 18

Service

Reassembly

1.If it was necessary to remove the piston ball housing (9) from the displacement rod (1), clean the threads of the rod and the ball housing, and apply thread sealant. Screw the ball housing onto the rod, hand tight. Place the flats of the piston ball housing in a vise and torque the rod to 258–285 NSm (190–210ft-lb). See Fig. 9.

2.For standard displacement pump 236458, place the piston packings on the piston seat housing (10)

in the following order, with the lips of the v-pack- ings facing up: the female gland (4*), one PTFE r v-packing (18*), four leather v-packings (19*), and the male gland (3*). See the Piston Packing Detail in Fig. 9.

NOTE: To convert the pump to a different packing material, see page 24.

3.Place the flats of the piston seat housing (10) in a vise. Apply thread sealant to the threads of the piston seat housing. Place the ball (12*) on the seat. Screw the piston ball housing (9) onto the piston seat housing hand tight, then torque

to 258–285 NSm (190–210 ft-lb). See Fig. 7.

4.For standard displacement pump 236458, lubricate the throat packings and place them in the outlet housing (6) in the following order, with the lips of

the v-packings facing down: the male gland (3*), four leather v-packings (19*), one PTFErv-pack- ing (18*), and the female gland (4*). See the Throat Packing Detail in Fig. 9.

NOTE: To convert the pump to a different packing material, see page 24.

5.Lubricate the threads of the packing nut (8), and loosely install it in the outlet housing (6).

6.Lubricate the piston packings. Slide the displace- ment rod (1) and piston assembly down into the cylinder (2). The cylinder is symmetrical, so either end may face up. Use a rubber mallet to drive the rod into the cylinder, until the piston seat housing (10) is located in the middle of the cylin- der.

7.Install the seal (11*) on the top of the cylinder (2). Lubricate the seal and the top threads of the cylinder.

8.Place the outlet housing (6) in a vise, as shown in Fig. 8. Slide the displacement rod (1) up into the outlet housing, then screw the cylinder (2) into the outlet housing handtight. The threads will engage easily until the seal (11*) contacts the sealing surface of the outlet housing. The top of the rod will protrude from the packing nut (8).

6

1

2

5 3

7 1

11*

2

1

8

1

Torque to 325–353 NSm (240–260 ft-lb).

 

2

Lubricate.

 

3

Torque to 190–217 NSm (140–160 ft-lb).

05127

Fig. 8

18 308350

Image 18 Contents
Instructions Parts List Dura-Flot600 PumpsTable of Contents List of ModelsSymbols Equipment Misuse HazardInjection Hazard Moving Parts HazardFire and Explosion Hazard Toxic Fluid Hazard308350 General Information Grounding InstallationSystem Accessories Object being sprayed follow your local codeAir Line Accessories Typical Installation KEYPacking Nut/Wet-Cup Operation/MaintenancePressure Relief Procedure 110Starting and Adjusting the Pump Flush the Pump Before First UseShutdown and Care of the Pump FlushingTroubleshooting Chart Its stroke keep the wet-cup 1/3 filled with aCompatible solvent Reconnecting the Displacement Pump Service Disconnecting the Displacement Pump Required Tools101 105 108 107 106 110 109Displacement Pump Service DisassemblyTorque to 258-285 NSm 190-210 ft-lb Reassembly 10 Ref 11 Ref Sealing surface of the intake housing Install the seal 11* on the bottomHousing 7 onto the cylinder handtight. Using a pipe wrench, torque the intake housingParts 101 105 108 109 102Y 107 106 110102Y 107 106 110 102Y 107 110 106 112 Part No Pump, Series a 251 Ratio, with Senator Air Motor101 105 108 109 113Throat Packing Stack see Piston Packing Stack SeeUHMWPE/Leather Packing Kit 237238 Optional Packing KitsTeflonr Packing Kit 237236 Optional UHMWPE/PTFErPacking Kit 237609 OptionalTechnical Data Tested in accordance with ISOLiters/min 11.4 Dimensions Mounting Hole LayoutGraco Standard Warranty Graco Information