Hitachi 236464 manual Shutdown and Care of the Pump, Flushing

Page 12

Operation/Maintenance

Shutdown and Care of the Pump

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10.

For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the throat packings. Relieve the pressure.

Always flush the pump before the fluid dries on the displacement rod. See Flushing below.

Flushing

WARNING

FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE AND EXPLOSION HAZARD on page 5. Be sure the entire system and flushing pails are properly grounded. Refer to Grounding on page 7.

Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency. Always flush the pump before fluid dries on the dis- placement rod.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10.

1.Relieve the pressure.

2.Remove the spray tip from the gun.

3.Hold a metal part of the gun firmly to the side of a grounded metal pail.

4.Start the pump. Always use the lowest possible fluid pressure when flushing.

5.Trigger the gun.

6.Flush the system until clear solvent flows from the gun.

7.Relieve the pressure.

12 308350

Image 12 Contents
Instructions Parts List Dura-Flot600 PumpsTable of Contents List of ModelsSymbols Equipment Misuse HazardInjection Hazard Moving Parts HazardFire and Explosion Hazard Toxic Fluid Hazard308350 Installation System AccessoriesGeneral Information Grounding Object being sprayed follow your local code Air Line Accessories Typical Installation KEYOperation/Maintenance Pressure Relief ProcedurePacking Nut/Wet-Cup 110Starting and Adjusting the Pump Flush the Pump Before First UseShutdown and Care of the Pump FlushingTroubleshooting Chart Its stroke keep the wet-cup 1/3 filled with aCompatible solvent Service Disconnecting the Displacement PumpReconnecting the Displacement Pump Required Tools101 105 108 107 106 110 109Displacement Pump Service DisassemblyTorque to 258-285 NSm 190-210 ft-lb Reassembly 10 Ref 11 Ref Install the seal 11* on the bottom Housing 7 onto the cylinder handtight.Sealing surface of the intake housing Using a pipe wrench, torque the intake housingParts 101 105 108 109 102Y 107 106 110102Y 107 106 110 Part No Pump, Series a 251 Ratio, with Senator Air Motor 101 105 108 109102Y 107 110 106 112 113Throat Packing Stack see Piston Packing Stack SeePacking Kits Teflonr Packing Kit 237236 OptionalUHMWPE/Leather Packing Kit 237238 Optional UHMWPE/PTFErPacking Kit 237609 OptionalTechnical Data Tested in accordance with ISOLiters/min 11.4 Dimensions Mounting Hole LayoutGraco Standard Warranty Graco Information