Hitachi 236464 manual Installation, General Information Grounding, System Accessories

Page 7

Installation

General Information

NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing.

NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor. Refer to Product Data Sheet, Form No. 305724. If you supply your own accessories, be sure they are adequately sized and pressure rated for your system.

Grounding

WARNING

FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read the section FIRE AND EXPLOSION HAZARD on page 5.

3.Air compressor: follow manufacturer’s recommen- dations.

4.Spray gun: ground through connection to a prop- erly grounded fluid hose and pump.

5.Fluid supply container: follow your local code.

6.Object being sprayed: follow your local code.

7.Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continu- ity.

8.To maintain grounding continuity when flushing or relieving pressure, hold a metal part of the spray gun firmly to the side of a grounded metal pail, then trigger the gun.

1.Pump: use a ground wire and clamp. See Fig. 1. Loosen the grounding lug locknut (W) and washer (X). Insert one end of a 1.5 mm@ (12 ga) minimum ground wire (Y) into the slot in lug (Z) and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order Part No. 237569 Ground Wire and Clamp.

W

X

Y

Z

0864

Fig. 1

2.Air and fluid hoses: use only electrically conductive hoses.

System Accessories

Fig. 2 is only a guide for selecting and installing sys- tem components and accessories. Contact your Graco distributor for assistance in designing a system to suit your particular needs.

Air and Fluid Hoses

Be sure all air hoses (H) and fluid hoses (N and P) are properly sized and pressure-rated for your system. Use only electrically conductive hoses. Fluid hoses must have spring guards on both ends. Use a whip hose (P) and a swivel (R) between the main fluid hose (N) and the gun (S) to allow freer gun movement.

Mounting Accessories

Mount the pump (A) to suit the type of installation planned. Fig. 2 illustrates a wall mount system. Pump dimensions and the mounting hole layout are shown on page 27.

If you are using a floor stand, refer to its separate manual for installation and operation instructions.

308350 7

Image 7 Contents
Dura-Flot600 Pumps Instructions Parts ListList of Models Table of Contents Equipment Misuse Hazard SymbolsMoving Parts Hazard Injection HazardToxic Fluid Hazard Fire and Explosion Hazard308350 Object being sprayed follow your local code InstallationSystem Accessories General Information GroundingAir Line Accessories KEY Typical Installation110 Operation/MaintenancePressure Relief Procedure Packing Nut/Wet-CupFlush the Pump Before First Use Starting and Adjusting the PumpFlushing Shutdown and Care of the PumpIts stroke keep the wet-cup 1/3 filled with a Troubleshooting ChartCompatible solvent Required Tools ServiceDisconnecting the Displacement Pump Reconnecting the Displacement Pump107 106 110 109 101 105 108Disassembly Displacement Pump ServiceTorque to 258-285 NSm 190-210 ft-lb Reassembly 10 Ref 11 Ref Using a pipe wrench, torque the intake housing Install the seal 11* on the bottomHousing 7 onto the cylinder handtight. Sealing surface of the intake housing101 105 108 109 102Y 107 106 110 Parts102Y 107 106 110 113 Part No Pump, Series a 251 Ratio, with Senator Air Motor101 105 108 109 102Y 107 110 106 112Piston Packing Stack See Throat Packing Stack seeUHMWPE/PTFErPacking Kit 237609 Optional Packing KitsTeflonr Packing Kit 237236 Optional UHMWPE/Leather Packing Kit 237238 OptionalTested in accordance with ISO Technical DataLiters/min 11.4 Mounting Hole Layout DimensionsGraco Information Graco Standard Warranty