Kenmore 300 Series, 300 Series SET Water Hardness Number, SET Regeneration Time, SET Salt Level

Page 19

Program The Timer

SET WATER HARDNESS NUMBER

To set the water hardness number, complete the follow- ing steps:

1.Press the SELECT button once to display the words SET HARDNESS and a flashing 25. The grains per gallon (gpg) hardness of your water supply is on your water analysis report. Be sure to enter water test results on the Facts & Figure Chart on page 3.

2.If your water supply contains iron, compensate for it by adding to the water hardness number. For exam- ple, assume your water is 20 gpg hard and contains 2 ppm iron. Add 5 to the hardness number for each I ppm of iron. In this example, you would use 30 for your hardness number.

2 ppm iron x 5 = 10

20 gpg hardness

+10

30 HARDNESS NUMBER

3.Press the UP or DOWN buttons to set your water hardness number in the display. The DOWN button moves the display to 1. The UP button moves the display to the highest setting (see maximum setting for your model in the specifications).

NOTE: Each press of the UP or DOWN button changes the display by 1 between 1 and 25. Between 25 and the highest number, the display changes 5 at a time (25, 30, 35, etc.) Holding the UP or DOWN button in changes the display twice each second.

SET REGENERATION TIME

To complete setting the regeneration time, complete the following steps:

1.Press the SELECT button to display the words SET RECHARGE TIME and a flashing 2:00 AM.

2.At the 2:00 AM recharge time setting, the softener begins regeneration (see pages 25 - 27) at 2:00 AM. This is a good time in most households because water is not being used. If a different recharge time setting would be better for your household, complete the following step.

3.Press the UP or DOWN buttons to set the desired recharge starting hour. Be sure to observe the AM- PM as you did when setting the present time of day.

Note: Each press of the UP or DOWN buttons changes the display one hour. Holding the but- tons in changes the display twice each second.

SET SALT LEVEL

To set the salt level, complete the following steps:

1.Press the SELECT button to display SET SALT LEVEL and a flashing 0 (zero). See page 21, for instructions on adding salt to the salt storage tank. The face plate timer has a salt monitor with an indi- cator light to remind you to add salt to the storage tank.

NOTE:You must set salt level each time salt is added to the water softener.

2.To set this monitor system, lift the salt hole cover and level the salt in the storage tank. The salt level decal, on the brinewell inside the tank, has numbers from 0 to 8. Observe the highest number the leveled salt is at, or closest to. Press the UP or DOWN but- tons until the number corresponds with the salt level number. At level 2 or below, the indicator LED will flash. If you wish to turn this feature off, press the DOWN button past 0, and the word “OFF” flashes in the display.

3.Press the SELECT button once again, to complete initial programming, and the current time of day will show in the display.

FIG. 27

Questions? Call The Kenmore Water Line 1-800-426-9345

19

Image 19
Contents Save this Manual Repair or Parts ? Call toll freeTEN Year Limited Warranty Against Leaks ONE Year Limited Warranty on Water SoftenerDisclaimer of implied warranties limitation of remedies Facts and Figures to Keep Table of ContentsSafety Guides Inspect Shipment Unpack and Check Your CartonParts Descriptions Small PartsTools Needed Plan Your InstallationProper Order to Install Water Treating Equipment Plan Your InstallationWhere to Install the Water Softener Typical InstallationDraw in Your Pipes and Fittings Suggested Slab Foundation InstallationPIPE, FITTINGS, Other Materials Needed OUTBefore Installing Checks & Tests Read Before Beginning InstallationAssemble Inlet Outlet ADAPTORS, or Plastic Bypass Valve Install Plastic Bypass ValveBypass Valve Valve Bypass Install 3-Valve BypassInstalling Holding Clips Installing 3 Valve Bypass and PipesPosition Softener Into Place Locate Water Softener and Connect PipesMove Softener Into Place Typical Soldering ConnectionsConnect the Valve Drain Hose Connect Valve and Salt Tank DrainsConnect Salt Tank Overflow Tubing Leak Test Leak TestHouse Main Water Shutoff Valves Single BypassCold Water Pipe Grounding Water Meter Jumper WireConnecting Transformer Electrical RequirementsRestart the Water Heater Install Covers and Restart Water HeaterInstall Covers Install CoversProgram the Timer Program The TimerSET Present Time of DAY SET Regeneration Time SET Water Hardness NumberSET Salt Level Sanitize the Water Softener Sanitize The Water SoftenerSanitize Your Water Softener AS Follows Adding Salt to the Storage Tank Adding Salt To The Storage TankWater Softening Salt with Iron Removing Additives Check List Check List of STEP-BY-STEP Guides to InstallRecharge Tonight Faceplate Timer FeaturesExtra Recharge Recharge NOWProgram Memory Efficiency ModeError Code To turn this setting onWater Flow Through Softener in Fill Water Flow Through Softener in ServiceSoft Water Service and Regeneration How Your Water Softener WorksWater Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseAutomatic Bypass Water Flow Through Softener Fast RinseElectronics Salt Bridge Care Of Your Water SoftenerSalt Bridge Iron from Resin BED Keeping the Water Softener CleanNozzle & Venturi Protect the Water Softener from Freezing Drain ALL Water from SoftenerChecklist to Help YOU Save Money Problem Cause CorrectionInches SpecificationsModel 38306 Timer Code S Model 39306 Timer Code S Bypass ValvesOther Specifications Always Make These Initial Checks First Service Tech InformationWiring Schematic FaceplatePossible Defect Code Procedure for Removing Error Code from FaceplateModel Troubleshooting Valve Position IndicatorsTimer PWA Replacement Other InformationManual Advance Regeneration Check Brine Valve Float SettingCycle Flow Rates Gallons PER MIN To Relieve Pressure Rotary Valve ServiceDisassembly AssemblyFill Cycle Water Flow Through the Softener Valve Service CycleBrining and Brine Rinse Cycle Fast Rinse Cycle Water Flow Through the Softener Valve Backwash CycleFast Rinse Cycle Backwash CycleQuestions? Call The Kenmore Water Line Exploded View Water Softener Complete Parts ListPart Number Part Description Inlet Outlet Grounding Clamps Brine Valve Assembly Seal Key Part Number Part Description Get it fixed, at your home or ours