Kenmore 300 Series, 300 Series warranty Faceplate Timer Features, Extra Recharge, Recharge NOW

Page 23

Faceplate Timer Features

EXTRA RECHARGE

Sometimes, a manually started regeneration (recharge) may be desired, or needed. Two examples are:

You have used more water than usual (guests visiting) and you may run out of soft water before the next timer started regeneration.

You did not refill the softener with salt before it was gone. Add salt to the softener before regenerating.

You can start a regeneration right away, or you can set the timer to regenerate at the next 2:00 AM (or other pre- set recharge time).

RECHARGE NOW

Press the REGENERATION button and hold for 3 sec- onds. The words RECHARGE NOW begin to flash in the display, and the softener enters the fill cycle of regenera- tion right away. This regeneration will last for about 2 hours. Then, you will have soft water again.

RECHARGE TONIGHT

Press and release (do not hold) the REGENERATION button. RECHARGE TONIGHT flashes in the display, and the softener begins regeneration at the next preset recharge time. Press and release the RECHARGE but- ton once more if you decide to cancel the regeneration, and RECHARGE TONIGHT will not flash in the display.

SALT MONITOR SYSTEM

The face plate timer has a low salt monitor with an indi- cator light to remind you to add salt to the storage tank.

To set this monitor system:

1.Lift the salt hole cover and level the salt in the storage tank.

2.The salt level decal, on the brinewell inside the tank, has numbers from 0 to 8. Observe the number the lev- eled salt is at or closest to.

3.Press SELECT once to get to the Set Salt Level screen. Now press the UP or DOWN buttons until the number corresponds with the salt level number. At level 2 or below, the indicator LED will flash. If you wish to turn this feature off, press the DOWN button past 0, and the word “OFF” flashes in the display.

NOTE: You must set salt level each time salt is added to the water softener.

FIG. 31

FIG. 32

FIG. 33

Questions? Call The Kenmore Water Line 1-800-426-9345

23

Image 23
Contents Save this Manual Repair or Parts ? Call toll freeDisclaimer of implied warranties limitation of remedies ONE Year Limited Warranty on Water SoftenerTEN Year Limited Warranty Against Leaks Facts and Figures to Keep Table of ContentsSafety Guides Inspect Shipment Unpack and Check Your CartonParts Descriptions Small PartsTools Needed Plan Your InstallationProper Order to Install Water Treating Equipment Plan Your InstallationWhere to Install the Water Softener Typical InstallationDraw in Your Pipes and Fittings Suggested Slab Foundation InstallationPIPE, FITTINGS, Other Materials Needed OUTBefore Installing Checks & Tests Read Before Beginning InstallationBypass Valve Install Plastic Bypass ValveAssemble Inlet Outlet ADAPTORS, or Plastic Bypass Valve Valve Bypass Install 3-Valve BypassInstalling Holding Clips Installing 3 Valve Bypass and PipesPosition Softener Into Place Locate Water Softener and Connect PipesMove Softener Into Place Typical Soldering ConnectionsConnect Salt Tank Overflow Tubing Connect Valve and Salt Tank DrainsConnect the Valve Drain Hose Leak Test Leak TestHouse Main Water Shutoff Valves Single BypassCold Water Pipe Grounding Water Meter Jumper WireConnecting Transformer Electrical RequirementsRestart the Water Heater Install Covers and Restart Water HeaterInstall Covers Install CoversSET Present Time of DAY Program The TimerProgram the Timer SET Salt Level SET Water Hardness NumberSET Regeneration Time Sanitize Your Water Softener AS Follows Sanitize The Water SoftenerSanitize the Water Softener Water Softening Salt with Iron Removing Additives Adding Salt To The Storage TankAdding Salt to the Storage Tank Check List Check List of STEP-BY-STEP Guides to InstallRecharge Tonight Faceplate Timer FeaturesExtra Recharge Recharge NOWProgram Memory Efficiency ModeError Code To turn this setting onWater Flow Through Softener in Fill Water Flow Through Softener in ServiceSoft Water Service and Regeneration How Your Water Softener WorksWater Flow Through Softener in Backwash Water Flow Through Softener Brining and Brine RinseElectronics Water Flow Through Softener Fast RinseAutomatic Bypass Salt Bridge Care Of Your Water SoftenerSalt Bridge Nozzle & Venturi Keeping the Water Softener CleanIron from Resin BED Protect the Water Softener from Freezing Drain ALL Water from SoftenerChecklist to Help YOU Save Money Problem Cause CorrectionInches SpecificationsModel 38306 Timer Code S Model 39306 Timer Code S Bypass ValvesOther Specifications Always Make These Initial Checks First Service Tech InformationWiring Schematic FaceplatePossible Defect Code Procedure for Removing Error Code from FaceplateModel Troubleshooting Valve Position IndicatorsTimer PWA Replacement Other InformationCycle Flow Rates Gallons PER MIN Brine Valve Float SettingManual Advance Regeneration Check To Relieve Pressure Rotary Valve ServiceDisassembly AssemblyBrining and Brine Rinse Cycle Water Flow Through the Softener Valve Service CycleFill Cycle Fast Rinse Cycle Water Flow Through the Softener Valve Backwash CycleFast Rinse Cycle Backwash CycleQuestions? Call The Kenmore Water Line Exploded View Part Number Part Description Parts ListWater Softener Complete Inlet Outlet Grounding Clamps Brine Valve Assembly Seal Key Part Number Part Description Get it fixed, at your home or ours