Kenmore 625.348460 owner manual Service TECH. Information 5A.TROUBLESHOOTING

Page 19

SECTION 5

SERVICE TECH. INFORMATION

5A.TROUBLESHOOTING

KEEP THIS MANUAL WITH YOUR WATER SOFTENER. IF REPAIRS ARE NEEDED, THE SERVICE TECHNIB CIAN MUST HAVE THE INFORMATION ON THE FOLLOWING PAGES. FOR TELEPHONE ASSISTANCE, CALL TOLL FREE, NUMBER 1-800-426-9345.

ALWAYS MAKE THESE INITIAL CHECKS FIRST

1. Does the time display show the correct time of day?

--If display is blank, check power source to the softener.

--If time is flashing, power was off for over 6 hours. The softener resumes normal operation but regenB erations occur at the wrong time.

--If an error code (Example: Err 03) shows in the face plate display, go to AUTOMATIC ELECTRONIC

DIAGNOSTICS.

2. Plumbing bypass valve(s) must be in Full Service position.

3. The inlet and outlet pipes must connect to the softener valve inlet and outlet respectively.

4. Is the transformer plugged into a •live", grounded wall outlet, and is the power cable fastened securely?

5. The valve drain hose must be free of kinks and sharp

bends, and not elevated over 8 ft. above the floor.

REMOVE THE TOP COVER AND SALT TANK COVER

6. Is there salt in the storage tank?

7. Is the brine tubing connected? (See water flow diagrams).

8. Is the brine valve float set right? (See page 22).

9. Press the SELECT button 2 times to display the hardness setting. Be sure it is the correct setting for the household's water supply. (Make a hardness test of the raw water and compare with the hardness setting. Also test a soft water sample to verify if a problem exists.) Press SELECT 3 times to return the time of day display.

If you do not find the problem after making initial checks, do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS, and the MANUAL ADVANCE REGENERATION CHECK.

19

Image 19
Contents Save this Manual Model noSears Installation Policy Sears Installation Warranty WarrantyFull ONE Year Warranty on Water Softener Full TEN Year Warranty Against LeaksSoftener Start UP Table of ContentsService Tech Information Repair PartsSection Water Softener START-UP Safety Guides± Valve Bypass Plastic Bypass Brass Bypass Water Heater SET Present Time of DAY Note Water Softener START-UP 1C.PROGRAM the TimerSET Water Hardness Number SET ``CLEAN FeatureSET Recharge Regeneration Time ADD Water Water Softener START-UP 1D. Sanitizing the Water SoftenerADD Salt Water Softener START-UP 1E. Fill the Storage Tank with SaltProgram Memory HOW Your Water Softener Works 2A.FACE Plate Timer FeaturesError Code Extra RechargeFill Backwash Brining Fast Rinse Brine Rinse ServiceWater Flow Through the Softener in Brining and Brine Rinse Electronics Automatic BypassPlease see page 9 for Salt Filling Directions Salt BridgeIron from the Resin BED Care of Your Softener 3D. Keeping the Water Softener CleanCovers Nozzle and VenturiDrain Water from the Softener Care of Your Softener 3D. Keep the Softener from FreezingProblem Cause Correction Water has Salty Timer SC Code SC21 Other Things to Know 4A.DIMENSIONS/SPECIFICATIONSBypass Valves Always Make These Initial Checks First Service TECH. Information 5A.TROUBLESHOOTINGManual Initiated Electronics Diag Nostics Automatic Electronic Diagnostics± ± Correct Switch Displays Valve Cycle StatusCycle Flow Rates Gallons PER MIN Manual Advance Regeneration CheckServicing the Valve Service TECH. Information 5B.ROTARY Valve ServiceDisassembly AssemblyFill Cycle Service CycleBrining and Brine Rinse Cycles Backwash and ``CLEAN CycleFast Rinse Cycle Service TECH. Information Sears Water Softener Tubing Assem. Incl. Key No Valve Assembly KEY Part Owners Manual