Operation when Programme Lock ON is set

*Suppose you want to set Programme Lock ON.

Procedure

1Press the CUSTOM SETTING pad

4. Audible Signal Sound Volume SettingTo Set Cooking Completion Signal Volume5. Cooking Completion Signal SettingTo Set the Signal Type x 2 twice within 2 seconds.

 

3

 

2

2

Enter 3, 2 for Programme Lock

 

 

 

ON.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Press the START pad to save the

 

 

 

 

 

setting.

4 Press the STOP/CLEAR pad to exit from the Custom Setting function.

NOTE : If you select Programme Lock OFF, the LOCK indicator in the display will disappear when you press the START pad.

Operation when Programme Lock ON is set

KEY

Custom Setting Title

When Programme

Operation

Lock ON is Set

 

 

 

 

1

Selecting Memory

no operation

Input Method

 

 

 

 

 

 

2

Selecting Auto Start

no operation

Operation

 

 

 

 

 

 

3

Programme Lock

operation

Setting

 

 

 

 

 

 

4

Audible Signal Sound

no operation

Volume Setting

 

 

 

 

 

 

5

Cooking Completion

no operation

Signal Setting

 

 

 

 

 

 

6

Memory Check

operation

 

 

 

 

Counter Check/Clear

check : operation

7

 

clear :

 

 

no operation

 

 

 

 

Air Intake Filter

check, clear :

8

Counter

operation

 

 

set : no operation

 

 

 

 

Selecting Operation

no operation

9in Case of Magnetron Failure

 

Multiplication Factors

check : operation

x2/x3

for Double/Triple

set : no operation

 

Quantity

 

 

 

 

EXPRESS

Express Defrost

check : operation

DEFROST

Setting

set : no operation

10

4. Audible Signal Sound Volume Setting

The volume of the audible signal can be adjusted to High, Medium, or Mute.

CU41 : High = factory Setting

CU42 : Medium

CU43 : Mute

To Set Cooking Completion Signal Volume

Press the CUSTOM SETTING pad twice within 2 seconds then enter the numbers

4, 1 for High

4, 2 for Medium 4, 3 for Mute

Press the START pad to save setting and the STOP/CLEAR pad to exit from the Custom Setting function.

NOTE : Even when errors occur, your oven will not beep in mute setting.

5. Cooking Completion Signal Setting

There is a choice of 4 different signals on your oven. CU51 : 1 long beep = factory setting

CU52 : Repeating long beeps

CU53 : 4 short beeps

CU54 : Repeating short beeps

To Set the Signal Type

Press the CUSTOM SETTING pad twice within 2 seconds then enter the numbers

5, 1 for 1 long beep

5, 2 for repeating long beeps 5, 3 for 4 short beeps

5, 4 for repeating short beeps

Press the START pad to save settings and the STOP/CLEAR pad to exit from the Custom Setting function.

6. Memory Check

Use this setting to check the programming for a certain memory.

*Suppose you want to know the information programmed into memory 1, programmed for 4 minutes at 60% for the 1st stage and 2 minutes at 30% at the 2nd stage programmed Dual Digit Input.

ProcedureDisplay

6. Memory Check x 2 6

1 Press the CUSTOM SETTING

NO. CHECK

 

pad twice within 2 seconds and

 

enter 6.

 

R-1900J [EN].indd Sec1:10

4/28/09 10:01:26 AM

Image 11
Contents OPERATION MANUAL AND COOKING GUIDE CONTENTSMODEL R-1900J COMMERCIAL MICROWAVE OVENa. Do not overcook food DON’T SPECIAL NOTES AND WARNINGSNOTE External Equipotential Earthing Terminal INSTALLATION INSTRUCTIONSOVEN DIAGRAM Memory Cooking OPERATION OF TOUCH CONTROL PANELMEMORY OPERATION Before OperationHELPFUL TIPS for the Display of Memory Input Status and the START Pad Cooking Double/Triple Quantity with Memoryx2/x3 ProcedureExpress Defrost with Memory MANUAL OPERATION2 3 3 0Food Express Defrost ChartExpress Defrost Repeat Cooking1. Selecting Memory Input Method Custom SettingPROGRAMME AND CUSTOMISE 3. Programme Lock Setting5. Cooking Completion Signal Setting Operation when Programme Lock ON is set4. Audible Signal Sound Volume Setting To Set Cooking Completion Signal Volumememory usage To Check More than One CounterTotal each Input memory number8. Air Intake Filter Counter x 2 8To Reset the Counter to “0” To Reset the Air Intake Filter Counter10. Multiplication Factors for Double/Triple Quantity 2 5x 2 x2/x3 Air Filter CyclePause Timing 11. Express Defrost Setting1. Setting time and power level for Single Stage Single Digit Input 1 0Saving Memories Dual Digit Input 4 0Repeat Digit Input 2. Programming Multi Stage Cooking 3. Setting Total Cooking Time of Express Defrost 3 0 0Demonstration Mode OTHER CONVENIENT FEATURESError Mode Maximum Cooking TimeExterior CARE AND CLEANINGMaintenance Mode CLEAN THE OVEN AT REGULAR INTERVALSHow to Install the Splash Cover Splash CoverHow to Remove the Splash Cover INPORTANT SERVICE CALL CHECKSPECIFICATIONS → →Utensil HELPFUL HINTSCOOKWARE AND UTENSIL GUIDE AdviceDEFROSTING TIME CHARTSDefrosting Chart FOODCOOKING TIME Cooking ChartMICROWAVE PREPARED DISHES Reheating ChartBREAKFAST HOT SANDWICHESSAVOURY BREAD AND PASTRY FRESH VEGETABLES CANNED FOODSSWEET PORTIONS MEAT PORTIONSCongratulations on Your Purchase WARRANTY PERIODSWARRANTY Consumer Electronic Products1300 135 SHARP APPROVED SERVICE CENTRESHARP APPROVED SERVICE CENTRE SHARP CUSTOMER SERVICES