electrolux 25
Loading info : Gas hob
Natural Gas
Heat input
Injector Marking L.P. Gas Heat input Injector Marking
R.H.F | R.H.R | L.H.R | L.H.F |
1.0kW (3412 Btu/ | 1.9kW (6483 Btu/ | 1.9kW (6483 Btu/ | 3.4kW (11600 |
h) | h) | h) | Btu/h) |
070 | 096 | 096 | 136 |
R.H.F | R.H.R | L.H.R | L.H.F |
1.0kW | 2.0kW | 2.0kW | 3.4kW |
050 (71.8g/h) | 071 (136.5g/h) | 071 (136.5g/h) | 093 (244.12g/h) |
|
|
|
|
Loading info : Grill
Heat input
Injector Marking
Loading info : Top oven
Heat input
Injector Marking
Dual control
Loading info : Main oven
Heat input Injector Marking Thermostat
Natural Gas
2.7kW (9212Btu/h) 120
Natural Gas
1.9kW (6483 Btu/h) 099 50
Natural Gas
1.9kW (6483 Btu/h) 099 75
L.P. Gas
2.7kW (194g/h) 95
L.P. Gas
1.9kW (136.5g/h) 070 38
L.P. Gas
1.9kW (136.5g/h) 070 80
General
Ignition (H.T. Spark)
GAS CATERGORY
CAT. I2H
CAT. I3+
Spark Gap
COUNTRIES OF DESTINATION
GB, IE
GB, IE
Environment concerns
The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for
the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council, your household waste disposal service or the shop where you purchased the product.